FCC Radar

FCC ID lookup › UNNECTO HOLDING LIMITED › 2ADR3UE020

FCC ID 2ADR3UE020

Mobile Phone

Company
UNNECTO HOLDING LIMITED (grantee code 2ADR3, Hong Kong)
Product code
UE020
Latest grant
Dec 22, 2025 — Original Equipment
Equipment classes
Digital Transmission System (DTS); PCS Licensed Transmitter held to ear (PCE); Part 15 Class B Computing Device Peripheral (JBP); Part 15 Low Power Communication Device Transmitter (DXX); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
QAI LABORATORIES LTD
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted Dec 22, 2025

Applications (6)

Equipment classApplication datedTCBBandsFCC record
Part 15 Low Power Communication Device Transmitter Dec 19, 2025 QAI LABORATORIES LTD
Burnaby, BC, Canada
1 Grant
Part 15 Class B Computing Device Peripheral Dec 19, 2025 QAI LABORATORIES LTD
Burnaby, BC, Canada
1 Grant
Digital Transmission System Dec 19, 2025 QAI LABORATORIES LTD
Burnaby, BC, Canada
2 Grant
Part 15 Spread Spectrum Transmitter Dec 19, 2025 QAI LABORATORIES LTD
Burnaby, BC, Canada
1 Grant
PCS Licensed Transmitter held to ear Dec 22, 2025 QAI LABORATORIES LTD
Burnaby, BC, Canada
45 Grant
Unlicensed National Information Infrastructure TX Dec 22, 2025 QAI LABORATORIES LTD
Burnaby, BC, Canada
4 Grant

Frequency bands (38)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
13.56 — 15C — — CC
2402 – 2480 9.6 mW 15C — — —
5180 – 5240 29.3 mW 15E — — CC
5260 – 5320 30.3 mW 15E — — CC ND
5500 – 5700 24.3 mW 15E — — CC ND
5745 – 5825 16.9 mW 15E — — CC
2402 – 2480 1.5 mW 15C — — CC
2412 – 2462 63.8 mW 15C — — CC
668 – 693 87.3 mW 27 2.5 PM 9M03W7D —
673 – 688 95.1 mW 27 2.5 PM 18M0G7D —
699.7 – 715.3 94.4 mW 27 2.5 PM 1M10W7D —
704 – 711 97.7 mW 27 2.5 PM 9M02G7D —
706.5 – 713.5 95.9 mW 27 2.5 PM 4M52G7D —
709 – 711 95.9 mW 27 2.5 PM 9M02G7D —
782 96.6 mW 27 2.5 PM 8M97G7D —
819 101.9 mW 90 2.5 PM 9M00G7D —
824.2 – 848.8 845.3 mW 22H 2.5 PM 246KGXW —
824.7 – 848.3 102.1 mW 22H 2.5 PM 1M10W7D —
826.4 – 846.6 90.8 mW 22H 2.5 PM 4M16F9W —
829 – 844 111.4 mW 22H 2.5 PM 9M03G7D —
831.5 – 841.5 85.1 mW 22H 2.5 PM 13M5G7D —
1711.5 – 1753.5 175 mW 27 2.5 PM 2M72W7D —
1712.6 – 1752.4 152.4 mW 27 2.5 PM 4M16F9W —
1717.5 – 1772.5 195 mW 27 2.5 PM 13M5W7D —
1720 – 1745 193.6 mW 27 2.5 PM 18M0G7D —
1720 – 1770 209.4 mW 27 2.5 PM 18M0G7D —
1850.2 – 1909.8 853.1 mW 24E 2.5 PM 251KGXW —
1852.4 – 1907.6 174.6 mW 24E 2.5 PM 4M16F9W —
1852.5 – 1912.5 184.5 mW 24E 2.5 PM 4M51W7D —
1857.5 – 1902.5 194.1 mW 24E 2.5 PM 13M6W7D —
1860 – 1900 214.8 mW 24E 2.5 PM 18M0G7D —
1860 – 1905 220.3 mW 24E 2.5 PM 18M0G7D —
2505 – 2565 186.2 mW 27 2.5 PM 9M02W7D —
2510 – 2560 214.8 mW 27 2.5 PM 18M1G7D —
2540 – 2650 255.3 mW 27 2.5 PM 9M02W7D —
2545 – 2645 260.6 mW 27 2.5 PM 17M9G7D —
2580 – 2610 221.8 mW 27 2.5 PM 18M0G7D —
— — 15B — — —

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Digital Transmission System. Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-wor… (688 characters, open to read all)

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission use conditions is 0.54W/kg, 0.62W/kg and 1.54W/kg respectively.

Part 15 Spread Spectrum Transmitter. Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific… (635 characters, open to read all)

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission use conditions is 0.13W/kg, 0.23W/kg and 1.15W/kg respectively.

PCS Licensed Transmitter held to ear. Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn … (686 characters, open to read all)

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission use conditions is 0.72W/kg, 0.92W/kg and 1.59W/kg respectively.

Unlicensed National Information Infrastructure TX. Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body… (692 characters, open to read all)

Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission use conditions is 0.87W/kg, 0.29W/kg and 1.59W/kg respectively.

History

Other devices by UNNECTO HOLDING LIMITED

All 7 FCC IDs of UNNECTO HOLDING LIMITED.

Recent DTS devices

Digital Transmission System devices granted closest in time to 2ADR3UE020.

All 18017 FCC IDs in class Digital Transmission System.

Recent PCE devices

PCS Licensed Transmitter held to ear devices granted closest in time to 2ADR3UE020.

All 493 FCC IDs in class PCS Licensed Transmitter held to ear.

Recent JBP devices

Part 15 Class B Computing Device Peripheral devices granted closest in time to 2ADR3UE020.

All 609 FCC IDs in class Part 15 Class B Computing Device Peripheral.

Recent DXX devices

Part 15 Low Power Communication Device Transmitter devices granted closest in time to 2ADR3UE020.

All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to 2ADR3UE020.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to 2ADR3UE020.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.