FCC Radar

FCC ID lookup › Fujian LANDI Commercial Equipment Co.,Ltd. › 2AG6N-P30A

FCC ID 2AG6N-P30A

Portable Data Terminal

Company
Fujian LANDI Commercial Equipment Co.,Ltd. (grantee code 2AG6N, China)
Product code
P30A
Latest grant
Apr 29, 2026 — Class II Permissive Change
Equipment classes
Digital Transmission System (DTS); PCS Licensed Transmitter (PCB); Part 15 Low Power Communication Device Transmitter (DXX); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
Kiwa Nederland B.V.
FCC record
Grant of equipment authorization at apps.fcc.gov

Class II Permissive Change — granted Apr 29, 2026

Grant 1 of 2 for this FCC ID.

Applications (5)

Equipment classApplication datedTCBBandsFCC record
Part 15 Spread Spectrum Transmitter Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant
PCS Licensed Transmitter Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
27 Grant
Digital Transmission System Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
2 Grant
Unlicensed National Information Infrastructure TX Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
4 Grant
Part 15 Low Power Communication Device Transmitter Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant

Frequency bands (18)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
2402 – 2480 7 mW 15C — — CC
13.56 — 15C — — CC
824.2 – 848.8 655 mW 22H 0.1 PM 245KGXW —
824.7 – 848.3 137 mW 22H 0.1 PM 8M98G7D —
826.4 – 846.6 117 mW 22H 0.1 PM 4M14F9W —
1710.7 – 1754.3 294 mW 27 0.1 PM 18M0G7D —
1712.4 – 1752.6 218 mW 27 0.1 PM 4M14F9W —
1850.2 – 1909.8 845 mW 24E 0.1 PM 245KGXW —
1850.7 – 1909.3 260 mW 24E 0.1 PM 18M0G7D —
1852.4 – 1907.6 247 mW 24E 0.1 PM 4M14F9W —
2502.5 – 2567.5 446 mW 27 0.1 PM 18M0G7D —
2572.5 – 2617.5 471 mW 27 0.1 PM 18M0G7D —
5180 – 5240 54 mW 15E — — CC
5260 – 5320 61 mW 15E — — CC ND
5500 – 5700 61 mW 15E — — CC ND
5745 – 5825 59 mW 15E — — CC
2402 – 2480 910 µW 15C — — CC
2412 – 2462 277 mW 15C — — CC

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Part 15 Spread Spectrum Transmitter. Class II Permissive Change. This change is : 1. The newly added series models only have an additional secondary screen a… (884 characters, open to read all)

Class II Permissive Change. This change is : 1. The newly added series models only have an additional secondary screen and power circuit for the secondary screen compared to the original models, and have no impact on the RF circuit. Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific(hotspot), extremity (hand) transmission exposure conditions are 0.27 W/kg, 0.55 W/kg, 1.76 W/kg, respectively.

PCS Licensed Transmitter. Class II Permissive Change. This change is : 1. The newly added series models only have an additional secondary screen a… (1208 characters, open to read all)

Class II Permissive Change. This change is : 1. The newly added series models only have an additional secondary screen and power circuit for the secondary screen compared to the original models, and have no impact on the RF circuit. Power Output is ERP for part 22 and 27(Below 1GHz) and EIRP for Part 24 and 27(Above 1GHz). This device has 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz and 20 MHz bandwidth modes for LTE Bands 2/4; 1.4 MHz, 3 MHz, 5 MHz and 10 MHz bandwidth modes for LTE Bands 5; 5 MHz, 10 MHz, 15 MHz and 20 MHz bandwidth modes for LTE Bands 7/38. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific(hotspot), extremity (hand) and simultaneous transmission exposure conditions are 0.91 W/kg, 1.07 W/kg, 2.12 W/kg and 1.56 W/kg, respectively.

Digital Transmission System. Class II Permissive Change. This change is : 1. The newly added series models only have an additional secondary screen a… (940 characters, open to read all)

Class II Permissive Change. This change is : 1. The newly added series models only have an additional secondary screen and power circuit for the secondary screen compared to the original models, and have no impact on the RF circuit. Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific(hotspot), extremity (hand) transmission exposure conditions are 0.07 W/kg, 0.66 W/kg, 2.25 W/kg, respectively. This device supports 20 MHz and 40 MHz bandwidth modes.

Unlicensed National Information Infrastructure TX. Class II Permissive Change. This change is : 1. The newly added series models only have an additional secondary screen a… (948 characters, open to read all)

Class II Permissive Change. This change is : 1. The newly added series models only have an additional secondary screen and power circuit for the secondary screen compared to the original models, and have no impact on the RF circuit. Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific(hotspot), extremity (hand) transmission exposure conditions are 0.41 W/kg, 0.77 W/kg, 1.60 W/kg, respectively. This device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes.

Part 15 Low Power Communication Device Transmitter. Class II Permissive Change. This change is : 1. The newly added series models only have an additional secondary screen and power circuit for the secondary screen compared to the original models, and have no impact on the RF circuit.

History

Original Equipment — granted Mar 2, 2026

Grant 2 of 2 for this FCC ID.

Applications (5)

Equipment classApplication datedTCBBandsFCC record
Unlicensed National Information Infrastructure TX Feb 12, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
4 Grant
Part 15 Low Power Communication Device Transmitter Feb 12, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant
Digital Transmission System Feb 12, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
2 Grant
PCS Licensed Transmitter Feb 12, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
27 Grant
Part 15 Spread Spectrum Transmitter Feb 12, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant

Frequency bands (18)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
13.56 — 15C — — CC
2402 – 2480 7 mW 15C — — CC
5180 – 5240 54 mW 15E — — CC
5260 – 5320 61 mW 15E — — CC ND
5500 – 5700 61 mW 15E — — CC ND
5745 – 5825 59 mW 15E — — CC
824.2 – 848.8 655 mW 22H 0.1 PM 245KGXW —
824.7 – 848.3 137 mW 22H 0.1 PM 8M98G7D —
826.4 – 846.6 117 mW 22H 0.1 PM 4M14F9W —
1710.7 – 1754.3 294 mW 27 0.1 PM 18M0G7D —
1712.4 – 1752.6 218 mW 27 0.1 PM 4M14F9W —
1850.2 – 1909.8 845 mW 24E 0.1 PM 245KGXW —
1850.7 – 1909.3 260 mW 24E 0.1 PM 18M0G7D —
1852.4 – 1907.6 247 mW 24E 0.1 PM 4M14F9W —
2502.5 – 2567.5 446 mW 27 0.1 PM 18M0G7D —
2572.5 – 2617.5 471 mW 27 0.1 PM 18M0G7D —
2402 – 2480 910 µW 15C — — CC
2412 – 2462 277 mW 15C — — CC

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Unlicensed National Information Infrastructure TX. Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configura… (715 characters, open to read all)

Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific(hotspot), extremity (hand) transmission exposure conditions are 0.41 W/kg, 0.77 W/kg, 1.60 W/kg, respectively. This device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes.

Digital Transmission System. Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configura… (707 characters, open to read all)

Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific(hotspot), extremity (hand) transmission exposure conditions are 0.07 W/kg, 0.66 W/kg, 2.25 W/kg, respectively. This device supports 20 MHz and 40 MHz bandwidth modes.

PCS Licensed Transmitter. Power Output is ERP for part 22 and 27(Below 1GHz) and EIRP for Part 24 and 27(Above 1GHz). This device has 1.4 MHz, 3 M… (975 characters, open to read all)

Power Output is ERP for part 22 and 27(Below 1GHz) and EIRP for Part 24 and 27(Above 1GHz). This device has 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz and 20 MHz bandwidth modes for LTE Bands 2/4; 1.4 MHz, 3 MHz, 5 MHz and 10 MHz bandwidth modes for LTE Bands 5; 5 MHz, 10 MHz, 15 MHz and 20 MHz bandwidth modes for LTE Bands 7/38. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific(hotspot), extremity (hand) and simultaneous transmission exposure conditions are 0.91 W/kg, 1.07 W/kg, 2.12 W/kg and 1.56 W/kg, respectively.

Part 15 Spread Spectrum Transmitter. Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configura… (651 characters, open to read all)

Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific(hotspot), extremity (hand) transmission exposure conditions are 0.27 W/kg, 0.55 W/kg, 1.76 W/kg, respectively.

History

Other devices by Fujian LANDI Commercial Equipment Co.,Ltd.

All 18 FCC IDs of Fujian LANDI Commercial Equipment Co.,Ltd..

Recent DTS devices

Digital Transmission System devices granted closest in time to 2AG6N-P30A.

All 18017 FCC IDs in class Digital Transmission System.

Recent PCB devices

PCS Licensed Transmitter devices granted closest in time to 2AG6N-P30A.

All 1088 FCC IDs in class PCS Licensed Transmitter.

Recent DXX devices

Part 15 Low Power Communication Device Transmitter devices granted closest in time to 2AG6N-P30A.

All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to 2AG6N-P30A.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to 2AG6N-P30A.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.