FCC Radar

FCC ID lookup › Shanghai Sunmi Technology Co.,Ltd. › 2AH25T5F2A

FCC ID 2AH25T5F2A

Portable Data Processing Terminal

Company
Shanghai Sunmi Technology Co.,Ltd. (grantee code 2AH25, China)
Product code
T5F2A
Latest grant
Apr 2, 2026 — Original Equipment
Equipment classes
15E 6 GHz Low Power Indoor Client (6XD); Digital Transmission System (DTS); PCS Licensed Transmitter (PCB); Part 15 Class B Computing Device Peripheral (JBP); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
Kiwa Nederland B.V.
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted Apr 2, 2026

Applications (6)

Equipment classApplication datedTCBBandsFCC record
Part 15 Spread Spectrum Transmitter Mar 16, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant
Part 15 Class B Computing Device Peripheral Mar 16, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant
Digital Transmission System Mar 16, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
2 Grant
15E 6 GHz Low Power Indoor Client Mar 16, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant
Unlicensed National Information Infrastructure TX Mar 16, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
4 Grant
PCS Licensed Transmitter Mar 16, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
50 Grant

Frequency bands (27)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
665.5 – 695.5 63 mW 27 2.5 PM 17M9G7D —
699.7 – 715.3 53 mW 27 2.5 PM 8M96G7D —
706.5 – 713.5 52 mW 27 2.5 PM 8M97G7D —
779.5 – 784.5 166 mW 27 2.5 PM 8M94G7D —
814.7 – 823.3 224 mW 90 2.5 PM 8M98G7D —
824.2 – 848.8 2.443 W 22H 2.5 PM 245KGXW —
824.7 – 848.3 206 mW 22H 2.5 PM 8M97G7D —
826.4 – 846.6 222 mW 22H 2.5 PM 4M10F9W —
1710.7 – 1754.3 240 mW 27 2.5 PM 17M9G7D —
1710.7 – 1779.3 237 mW 27 2.5 PM 17M9G7D —
1712.4 – 1752.6 262 mW 27 2.5 PM 4M11F9W —
1850.2 – 1909.8 1.18 W 24E 2.5 PM 244KGXW —
1850.7 – 1909.3 233 mW 24E 2.5 PM 17M9G7D —
1850.7 – 1914.3 236 mW 24E 2.5 PM 17M9G7D —
1852.4 – 1907.6 252 mW 24E 2.5 PM 4M11F9W —
2498.5 – 2687.5 455 mW 27 2.5 PM 17M9G7D —
2502.5 – 2567.5 451 mW 27 2.5 PM 17M9G7D —
2572.5 – 2617.5 452 mW 27 2.5 PM 17M9G7D —
— — 15B — — —
2402 – 2480 13 mW 15C — — CC
5925 – 7125 12 mW 15E — — CC EP MO
5180 – 5240 72 mW 15E — — CC MO
5260 – 5320 68 mW 15E — — CC MO ND
5500 – 5720 75 mW 15E — — CC MO ND
5745 – 5825 71 mW 15E — — CC MO
2402 – 2480 7.9 mW 15C — — CC
2412 – 2462 89 mW 15C — — CC MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Part 15 Spread Spectrum Transmitter. RF output power is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitter… (884 characters, open to read all)

RF output power is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.04 W/kg and 0.14 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.82 W/kg and 1.48 W/kg respectively.

Digital Transmission System. RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20 BW mode only. The antenna(s) used for th… (948 characters, open to read all)

RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20 BW mode only. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.09 W/kg and 0.27 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.87 W/kg and 1.61 W/kg respectively.

15E 6 GHz Low Power Indoor Client. RF output power is Effective Isotropic Radiated Power (EIRP). Device is a 2 x 2 MIMO configuration, supports 20, 40 and … (1061 characters, open to read all)

RF output power is Effective Isotropic Radiated Power (EIRP). Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.24 W/kg and 0.32 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.020 W/kg and 1.776 W/kg respectively. The highest reported power density (separation 2 mm) is 2.575 W/m2.

Unlicensed National Information Infrastructure TX. RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The antenna(s) … (959 characters, open to read all)

RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.23 W/kg and 1.35 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.46 W/kg and 1.80 W/kg respectively.

PCS Licensed Transmitter. Output power listed is ERP for operation below 1 GHz, EIRP for operation above 1 GHz, and conducted power for Part 90S (… (1334 characters, open to read all)

Output power listed is ERP for operation below 1 GHz, EIRP for operation above 1 GHz, and conducted power for Part 90S (814-824 MHz). LTE supports 1.4/3/5/10/15/20 MHz BW modes in Band 2/4/25/66, 1.4/3/5/10 MHz BW modes in Band 5/12, 5/10/15/20 MHz BW modes in Band 7/38/41/71, 1.4/3/5/10/15 MHz BW modes in Band 26, and 5/10 MHz BW modes in Band 13/17. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.78 W/kg and 1.46 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.46 W/kg and 1.82 W/kg respectively. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.

History

Other devices by Shanghai Sunmi Technology Co.,Ltd.

All 37 FCC IDs of Shanghai Sunmi Technology Co.,Ltd..

Recent 6XD devices

15E 6 GHz Low Power Indoor Client devices granted closest in time to 2AH25T5F2A.

All 289 FCC IDs in class 15E 6 GHz Low Power Indoor Client.

Recent DTS devices

Digital Transmission System devices granted closest in time to 2AH25T5F2A.

All 18017 FCC IDs in class Digital Transmission System.

Recent PCB devices

PCS Licensed Transmitter devices granted closest in time to 2AH25T5F2A.

All 1088 FCC IDs in class PCS Licensed Transmitter.

Recent JBP devices

Part 15 Class B Computing Device Peripheral devices granted closest in time to 2AH25T5F2A.

All 609 FCC IDs in class Part 15 Class B Computing Device Peripheral.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to 2AH25T5F2A.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to 2AH25T5F2A.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.