FCC ID lookup › Shanghai Sunmi Technology Co.,Ltd. › 2AH25T5F2AN
FCC ID 2AH25T5F2AN
Portable Data Processing Terminal
- Company
- Shanghai Sunmi Technology Co.,Ltd. (grantee code 2AH25, China)
- Product code
- T5F2AN
- Latest grant
- Jan 23, 2026 — Original Equipment
- Equipment classes
- 15E 6 GHz Low Power Indoor Client (6XD); Digital Transmission System (DTS); PCS Licensed Transmitter worn on body (PCT); Part 15 Class B Computing Device Peripheral (JBP); Part 15 Low Power Communication Device Transmitter (DXX); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
- Certified by
- Compliance Testing, LLC
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Original Equipment — granted Jan 23, 2026
Applications (7)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| 15E 6 GHz Low Power Indoor Client | Dec 5, 2025 | Compliance Testing, LLC Mesa, AZ, United States |
1 | Grant |
| Part 15 Class B Computing Device Peripheral | Dec 5, 2025 | Compliance Testing, LLC Mesa, AZ, United States |
1 | Grant |
| Digital Transmission System | Dec 5, 2025 | Compliance Testing, LLC Mesa, AZ, United States |
2 | Grant |
| PCS Licensed Transmitter worn on body | Dec 5, 2025 | Compliance Testing, LLC Mesa, AZ, United States |
50 | Grant |
| Part 15 Low Power Communication Device Transmitter | Dec 5, 2025 | Compliance Testing, LLC Mesa, AZ, United States |
1 | Grant |
| Part 15 Spread Spectrum Transmitter | Dec 5, 2025 | Compliance Testing, LLC Mesa, AZ, United States |
1 | Grant |
| Unlicensed National Information Infrastructure TX | Dec 5, 2025 | Compliance Testing, LLC Mesa, AZ, United States |
4 | Grant |
Frequency bands (41)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 673 – 688 | 67.5 mW | 27 | 2.5 PM | 17M9G7D | — |
| 699.7 – 715.3 | 43.3 mW | 27 | 2.5 PM | 1M10W7D | — |
| 704 – 711 | 57.4 mW | 27 | 2.5 PM | 8M97G7D | — |
| 709 – 711 | 55.7 mW | 27 | 2.5 PM | 9M00G7D | — |
| 779.5 – 784.5 | 137.1 mW | 27 | 2.5 PM | 4M50W7D | — |
| 782 | 184.5 mW | 27 | 2.5 PM | 8M97G7D | — |
| 814.7 – 823.3 | 210.4 mW | 90 | 2.5 PM | 1M10G7D | — |
| 819 | 204.2 mW | 90 | 2.5 PM | 8M92G7D | — |
| 824.2 – 848.8 | 2.3878 W | 22H | 2.5 PM | 248KGXW | — |
| 824.7 – 848.3 | 206.5 mW | 22H | 2.5 PM | 1M10G7D | — |
| 826.4 – 846.6 | 251.2 mW | 22H | 2.5 PM | 4M13F9W | — |
| 826.5 – 846.5 | 164.1 mW | 22H | 2.5 PM | 4M49W7D | — |
| 829 – 844 | 217.8 mW | 22H | 2.5 PM | 8M97G7D | — |
| 831.5 – 841.5 | 210.9 mW | 22H | 2.5 PM | 13M4G7D | — |
| 1710.7 – 1779.3 | 196.3 mW | 27 | 2.5 PM | 1M10W7D | — |
| 1711.5 – 1753.5 | 187.1 mW | 27 | 2.5 PM | 2M70W7D | — |
| 1712.4 – 1752.6 | 258.2 mW | 27 | 2.5 PM | 4M13F9W | — |
| 1720 – 1745 | 249.5 mW | 27 | 2.5 PM | 17M9G7D | — |
| 1720 – 1770 | 249.5 mW | 27 | 2.5 PM | 17M9G7D | — |
| 1850.2 – 1909.8 | 1.0814 W | 24E | 2.5 PM | 248KGXW | — |
| 1850.7 – 1909.3 | 180.3 mW | 24E | 2.5 PM | 1M10W7D | — |
| 1851.5 – 1913.5 | 179.1 mW | 24E | 2.5 PM | 2M70W7D | — |
| 1852.4 – 1907.6 | 250.6 mW | 24E | 2.5 PM | 4M12F9W | — |
| 1855 – 1910 | 234.4 mW | 24E | 2.5 PM | 8M98G7D | — |
| 1860 – 1900 | 249.5 mW | 24E | 2.5 PM | 17M9G7D | — |
| 1860 – 1905 | 225.9 mW | 24E | 2.5 PM | 17M9G7D | — |
| 2505 – 2565 | 476.4 mW | 27 | 2.5 PM | 8M97G7D | — |
| 2506 – 2680 | 432.5 mW | 27 | 2.5 PM | 17M9G7D | — |
| 2510 – 2560 | 472.1 mW | 27 | 2.5 PM | 17M9G7D | — |
| 2575 – 2615 | 277.3 mW | 27 | 2.5 PM | 8M97W7D | — |
| 2580 – 2610 | 420.7 mW | 27 | 2.5 PM | 17M9G7D | — |
| 2402 – 2480 | 13.2 mW | 15C | — | — | CC |
| 2402 – 2480 | 7.9 mW | 15C | — | — | CC |
| 2412 – 2462 | 89.1 mW | 15C | — | — | CC MO |
| 13.56 | — | 15C | — | — | CC |
| — | — | 15B | — | — | CC |
| 5180 – 5240 | 71.8 mW | 15E | — | — | CC MO |
| 5260 – 5320 | 67.6 mW | 15E | — | — | CC MO ND |
| 5500 – 5720 | 74.6 mW | 15E | — | — | CC MO ND |
| 5745 – 5825 | 70.8 mW | 15E | — | — | CC MO |
| 5955 – 7115 | 12.4 mW | 15E | — | — | CC EP MO |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
15E 6 GHz Low Power Indoor Client. RF output power is Effective Isotropic Radiated Power (EIRP). Device is a 2 x 2 MIMO configuration, supports 20, 40 and … (1058 characters, open to read all)
RF output power is Effective Isotropic Radiated Power (EIRP). Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.40 W/kg and 0.36 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.23 W/kg and 1.82 W/kg respectively. The highest reported power density (separation 2 mm) is 0.38 W/m2.
Digital Transmission System. RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20 BW mode only. The antenna(s) used for th… (948 characters, open to read all)
RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20 BW mode only. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.09 W/kg and 0.27 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.87 W/kg and 1.61 W/kg respectively.
PCS Licensed Transmitter worn on body. Output power listed is ERP for operation below 1 GHz, EIRP for operation above 1 GHz, and conducted power for Part 90S (… (1334 characters, open to read all)
Output power listed is ERP for operation below 1 GHz, EIRP for operation above 1 GHz, and conducted power for Part 90S (814-824 MHz). LTE supports 1.4/3/5/10/15/20 MHz BW modes in Band 2/4/25/66, 1.4/3/5/10 MHz BW modes in Band 5/12, 5/10/15/20 MHz BW modes in Band 7/38/41/71, 1.4/3/5/10/15 MHz BW modes in Band 26, and 5/10 MHz BW modes in Band 13/17. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.78 W/kg and 1.46 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.46 W/kg and 1.82 W/kg respectively. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.
Part 15 Spread Spectrum Transmitter. RF output power is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitter… (884 characters, open to read all)
RF output power is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.04 W/kg and 0.14 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.82 W/kg and 1.48 W/kg respectively.
Unlicensed National Information Infrastructure TX. RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The antenna(s) … (959 characters, open to read all)
RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.23 W/kg and 1.35 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.46 W/kg and 1.80 W/kg respectively.
History
- Oct 20, 2026: grant first recorded in FCC Radar.
Other devices by Shanghai Sunmi Technology Co.,Ltd.
All 37 FCC IDs of Shanghai Sunmi Technology Co.,Ltd..
Recent 6XD devices
15E 6 GHz Low Power Indoor Client devices granted closest in time to 2AH25T5F2AN.
All 289 FCC IDs in class 15E 6 GHz Low Power Indoor Client.
Recent DTS devices
Digital Transmission System devices granted closest in time to 2AH25T5F2AN.
All 18017 FCC IDs in class Digital Transmission System.
Recent PCT devices
PCS Licensed Transmitter worn on body devices granted closest in time to 2AH25T5F2AN.
All 113 FCC IDs in class PCS Licensed Transmitter worn on body.
Recent JBP devices
Part 15 Class B Computing Device Peripheral devices granted closest in time to 2AH25T5F2AN.
All 609 FCC IDs in class Part 15 Class B Computing Device Peripheral.
Recent DXX devices
Part 15 Low Power Communication Device Transmitter devices granted closest in time to 2AH25T5F2AN.
All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.
Recent DSS devices
Part 15 Spread Spectrum Transmitter devices granted closest in time to 2AH25T5F2AN.
All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.
Recent NII devices
Unlicensed National Information Infrastructure TX devices granted closest in time to 2AH25T5F2AN.
All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.