FCC Radar

FCC ID lookup › Juniper Networks, Inc. › 2AHBN-AP27

FCC ID 2AHBN-AP27

Wi-Fi 7 Wireless Access Point

Company
Juniper Networks, Inc. (grantee code 2AHBN, United States)
Product code
AP27
Latest grant
Oct 20, 2026 — Original Equipment
Equipment classes
15E 6 GHz Low Power Indoor Access Point (6ID); 15E 6 GHz Standard Power Access Point (6SD); Digital Transmission System (DTS); Unlicensed National Information Infrastructure TX (NII)
Certified by
IIA Lab Services, LLC
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted Oct 20, 2026

Grant 1 of 3 for this FCC ID.

Application (1)

Equipment classApplication datedTCBBandsFCC record
15E 6 GHz Standard Power Access Point Oct 16, 2026 IIA Lab Services, LLC
Alachua, FL, United States
2 Grant

Frequency bands (2)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
5955 – 6415 1.914 W 15E — — BX CC EP MO
6535 – 6855 2.099 W 15E — — BX CC EP MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. The ant… (638 characters, open to read all)

Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. The antennas used for this device must be installed to provide a separation distance from all persons as shown below, and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. AP27: 20 cm AP27E: 24 cm Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80, 160 and 320 MHz bandwidth modes. Device operation is limited to indoor use only.

History

Class II Permissive Change — granted Oct 20, 2026

Grant 2 of 3 for this FCC ID.

Applications (3)

Equipment classApplication datedTCBBandsFCC record
15E 6 GHz Low Power Indoor Access Point Oct 16, 2026 IIA Lab Services, LLC
Alachua, FL, United States
1 Grant
Digital Transmission System Oct 16, 2026 IIA Lab Services, LLC
Alachua, FL, United States
3 Grant
Unlicensed National Information Infrastructure TX Oct 16, 2026 IIA Lab Services, LLC
Alachua, FL, United States
4 Grant

Frequency bands (8)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
2402 – 2480 16 mW 15C — — CC
2405 – 2480 19 mW 15C — — CC
2412 – 2462 179 mW 15C — — CC MO
5180 – 5250 292 mW 15E — — CC MO
5250 – 5320 248 mW 15E — — CC MO ND
5500 – 5720 248 mW 15E — — CC MO ND
5745 – 5825 368 mW 15E — — CC MO
5955 – 7095 710 mW 15E — — CC EP MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

15E 6 GHz Low Power Indoor Access Point. Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. The ant… (790 characters, open to read all)

Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. The antennas used for this device must be installed to provide a separation distance from all persons as shown below, and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. AP27: 20 cm AP27E: 24 cm Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80, 160 and 320 MHz bandwidth modes. Device operation is limited to indoor use only. Class II Permissive Change: Addresses change to RF exposure minimum separation distance due to the addition of 6 GHz Standard Power Access Point modes.

Digital Transmission System. Output Power listed is the maximum combined conducted output power. This device must be installed to provide a separatio… (716 characters, open to read all)

Output Power listed is the maximum combined conducted output power. This device must be installed to provide a separation distance from all persons as shown below, and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. AP27: 20 cm AP27E: 24 cm Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 and 40 MHz bandwidth modes. Device operation is limited to indoor use only. Class II Permissive Change: Addresses a change to RF exposure minimum separation distance due to the addition of 6 GHz Standard Power Access Point modes.

Unlicensed National Information Infrastructure TX. Output Power listed is the maximum combined conducted output power. This device must be installed to provide a separatio… (725 characters, open to read all)

Output Power listed is the maximum combined conducted output power. This device must be installed to provide a separation distance from all persons as shown below, and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. AP27: 20 cm AP27E: 24 cm Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20, 40, 80 and 160 MHz bandwidth modes. Device operation is limited to indoor use only. Class II Permissive Change: Addresses a change to RF exposure minimum separation distance due to the addition of 6 GHz Standard Power Access Point modes.

History

Original Equipment — granted Apr 30, 2026

Grant 3 of 3 for this FCC ID.

Applications (3)

Equipment classApplication datedTCBBandsFCC record
Unlicensed National Information Infrastructure TX Apr 28, 2026 IIA Lab Services, LLC
Alachua, FL, United States
4 Grant
15E 6 GHz Low Power Indoor Access Point Apr 28, 2026 IIA Lab Services, LLC
Alachua, FL, United States
1 Grant
Digital Transmission System Apr 28, 2026 IIA Lab Services, LLC
Alachua, FL, United States
3 Grant

Frequency bands (8)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
5180 – 5250 292 mW 15E — — CC MO
5250 – 5320 248 mW 15E — — CC MO ND
5500 – 5720 248 mW 15E — — CC MO ND
5745 – 5825 368 mW 15E — — CC MO
5955 – 7095 710 mW 15E — — CC EP MO
2402 – 2480 16 mW 15C — — CC
2405 – 2480 19 mW 15C — — CC
2412 – 2462 179 mW 15C — — CC MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Unlicensed National Information Infrastructure TX. Output Power listed is the maximum combined conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance. This device supports 20, 40, 80 and 160 MHz bandwidth modes. Device operation is limited to indoor use only.
15E 6 GHz Low Power Indoor Access Point. Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. The ant… (615 characters, open to read all)

Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. The antennas used for this device must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80, 160 and 320 MHz bandwidth modes. Device operation is limited to indoor use only.

Digital Transmission System. Output Power listed is the maximum combined conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance. This device supports 20 and 40 MHz bandwidth modes. Device operation is limited to indoor use only.

History

Other devices by Juniper Networks, Inc.

All 8 FCC IDs of Juniper Networks, Inc..

Recent 6ID devices

15E 6 GHz Low Power Indoor Access Point devices granted closest in time to 2AHBN-AP27.

All 137 FCC IDs in class 15E 6 GHz Low Power Indoor Access Point.

Recent 6SD devices

15E 6 GHz Standard Power Access Point devices granted closest in time to 2AHBN-AP27.

All 59 FCC IDs in class 15E 6 GHz Standard Power Access Point.

Recent DTS devices

Digital Transmission System devices granted closest in time to 2AHBN-AP27.

All 18017 FCC IDs in class Digital Transmission System.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to 2AHBN-AP27.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.