FCC ID lookup › Fujian Centerm Information Co.,Ltd. › 2AN9R-CTAK10-Z
FCC ID 2AN9R-CTAK10-Z
Smart POS
- Company
- Fujian Centerm Information Co.,Ltd. (grantee code 2AN9R, China)
- Product code
- CTAK10-Z
- Latest grant
- Jun 10, 2026 — Original Equipment
- Equipment classes
- Digital Transmission System (DTS); PCS Licensed Transmitter worn on body (PCT); Part 15 Low Power Communication Device Transmitter (DXX); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
- Certified by
- QAI LABORATORIES LTD
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Original Equipment — granted Jun 10, 2026
Applications (5)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Part 15 Low Power Communication Device Transmitter | Jun 9, 2026 | QAI LABORATORIES LTD Burnaby, BC, Canada |
1 | Grant |
| Digital Transmission System | Jun 10, 2026 | QAI LABORATORIES LTD Burnaby, BC, Canada |
2 | Grant |
| PCS Licensed Transmitter worn on body | Jun 10, 2026 | QAI LABORATORIES LTD Burnaby, BC, Canada |
55 | Grant |
| Part 15 Spread Spectrum Transmitter | Jun 10, 2026 | QAI LABORATORIES LTD Burnaby, BC, Canada |
1 | Grant |
| Unlicensed National Information Infrastructure TX | Jun 10, 2026 | QAI LABORATORIES LTD Burnaby, BC, Canada |
4 | Grant |
Frequency bands (36)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 2402 – 2480 | 1.7 mW | 15C | — | — | CC |
| 2402 – 2480 | 2.4 mW | 15C | — | — | CC |
| 2412 – 2462 | 34.4 mW | 15C | — | — | CC |
| 668 – 693 | 106.2 mW | 27 | 2.5 PM | 8M98G7D | — |
| 673 – 688 | 92.5 mW | 27 | 2.5 PM | 17M9G7D | — |
| 704 – 711 | 119.4 mW | 27 | 2.5 PM | 8M99G7D | — |
| 709 – 711 | 115.1 mW | 27 | 2.5 PM | 8M98G7D | — |
| 782 | 139.6 mW | 27 | 2.5 PM | 8M98G7D | — |
| 793 | 135.2 mW | 90 | 2.5 PM | 8M95G7D | — |
| 815.5 – 822.5 | 137.7 mW | 90 | 2.5 PM | 2M68G7D | — |
| 819 | 135.5 mW | 90 | 2.5 PM | 8M96G7D | — |
| 824.2 – 848.8 | 1 W | 22H | 2.5 PM | 248KGXW | — |
| 825.5 – 847.5 | 130.6 mW | 22H | 2.5 PM | 2M68G7D | — |
| 826.4 – 846.6 | 124.7 mW | 22H | 2.5 PM | 4M22F9W | — |
| 829 – 844 | 130.3 mW | 22H | 2.5 PM | 8M96G7D | — |
| 831.5 – 841.5 | 120.2 mW | 22H | 2.5 PM | 13M5G7D | — |
| 1710.7 – 1779.3 | 283.8 mW | 27 | 2.5 PM | 1M09G7D | — |
| 1712.4 – 1752.6 | 269.8 mW | 27 | 2.5 PM | 4M23F9W | — |
| 1715 – 1750 | 282.5 mW | 27 | 2.5 PM | 8M96G7D | — |
| 1720 – 1745 | 272.9 mW | 27 | 2.5 PM | 17M9G7D | — |
| 1720 – 1770 | 274.2 mW | 27 | 2.5 PM | 18M0G7D | — |
| 1850.2 – 1909.8 | 1.4757 W | 24E | 2.5 PM | 245KGXW | — |
| 1851.5 – 1913.5 | 248.3 mW | 24E | 2.5 PM | 2M68G7D | — |
| 1852.4 – 1907.6 | 267.9 mW | 24E | 2.5 PM | 4M23F9W | — |
| 1860 – 1900 | 244.9 mW | 24E | 2.5 PM | 17M9G7D | — |
| 1860 – 1905 | 245.5 mW | 24E | 2.5 PM | 17M9G7D | — |
| 2505 – 2565 | 289.7 mW | 27 | 2.5 PM | 8M97G7D | — |
| 2506 – 2680 | 438.5 mW | 27 | 2.5 PM | 17M9G7D | — |
| 2510 – 2560 | 286.4 mW | 27 | 2.5 PM | 17M9G7D | — |
| 2575 – 2615 | 321.4 mW | 27 | 2.5 PM | 8M97G7D | — |
| 2580 – 2610 | 302 mW | 27 | 2.5 PM | 17M9G7D | — |
| 13.56 | — | 15C | — | — | CC |
| 5180 – 5240 | 28.2 mW | 15E | — | — | CC |
| 5260 – 5320 | 26.8 mW | 15E | — | — | CC ND |
| 5500 – 5700 | 24.2 mW | 15E | — | — | CC ND |
| 5745 – 5825 | 10.2 mW | 15E | — | — | CC |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Digital Transmission System. Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance … (1004 characters, open to read all)
Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific (wireless router) and simultaneous transmission use conditions is 0.29 W/kg, 0.29 W/kg and 1.42 W/kg respectively. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for extremity is 4.0 W/kg. The evaluation distance for extremity is 0 mm. The highest reported SAR for extremity and simultaneous transmission use conditions are 0.29 W/kg and 1.42 W/kg respectively.
PCS Licensed Transmitter worn on body. Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn … (989 characters, open to read all)
Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific (wireless router) and simultaneous transmission use conditions is 1.13W/kg, 1.13 W/kg and 1.55 W/kg respectively. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for extremity is 4.0 W/kg. The evaluation distance for extremity is 0 mm. The highest reported SAR for extremity and simultaneous transmission use conditions are 1.13 W/kg and 1.55 W/kg respectively.
Part 15 Spread Spectrum Transmitter. Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific… (939 characters, open to read all)
Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific (wireless router) and simultaneous transmission use conditions is 0.05 W/kg, 0.05 W/kg and 1.18 W/kg respectively. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for extremity is 4.0 W/kg. The evaluation distance for extremity is 0 mm. The highest reported SAR for extremity and simultaneous transmission use conditions are 0.05 W/kg and 1.18 W/kg respectively.
Unlicensed National Information Infrastructure TX. Power listed is the maximum conducted output power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR complia… (1007 characters, open to read all)
Power listed is the maximum conducted output power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific (wireless router) and simultaneous transmission use conditions is 0.42 W/kg, 0.42 W/kg and 1.55W/kg respectively. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for extremity is 4.0 W/kg. The evaluation distance for extremity is 0 mm. The highest reported SAR for extremity and simultaneous transmission use conditions are 0.42 W/kg and 1.55 W/kg respectively.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Other devices by Fujian Centerm Information Co.,Ltd.
Recent DTS devices
Digital Transmission System devices granted closest in time to 2AN9R-CTAK10-Z.
All 18017 FCC IDs in class Digital Transmission System.
Recent PCT devices
PCS Licensed Transmitter worn on body devices granted closest in time to 2AN9R-CTAK10-Z.
All 113 FCC IDs in class PCS Licensed Transmitter worn on body.
Recent DXX devices
Part 15 Low Power Communication Device Transmitter devices granted closest in time to 2AN9R-CTAK10-Z.
All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.
Recent DSS devices
Part 15 Spread Spectrum Transmitter devices granted closest in time to 2AN9R-CTAK10-Z.
All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.
Recent NII devices
Unlicensed National Information Infrastructure TX devices granted closest in time to 2AN9R-CTAK10-Z.
All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.