FCC ID lookup › SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD › 2ANMU-RT11
FCC ID 2ANMU-RT11
Tablet
- Company
- SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD (grantee code 2ANMU, China)
- Product code
- RT11
- Latest grant
- Aug 19, 2026 — Original Equipment
- Equipment classes
- Digital Transmission System (DTS); PCS Licensed Transmitter (PCB); Part 15 Low Power Communication Device Transmitter (DXX); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
- Certified by
- MiCOM Labs
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Original Equipment — granted Aug 19, 2026
Grant 1 of 2 for this FCC ID.
Applications (2)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Unlicensed National Information Infrastructure TX | Aug 19, 2026 | MiCOM Labs Pleasanton, CA, United States |
2 | Grant |
| Digital Transmission System | Aug 19, 2026 | MiCOM Labs Pleasanton, CA, United States |
2 | Grant |
Frequency bands (4)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 5180 – 5240 | 16.29 mW | 15E | — | — | CC |
| 5745 – 5825 | 14.66 mW | 15E | — | — | CC |
| 2402 – 2480 | 850 µW | 15C | — | — | CC |
| 2412 – 2462 | 42.56 mW | 15C | — | — | CC |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Unlicensed National Information Infrastructure TX. Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body… (671 characters, open to read all)
Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory is 0.25 W/kg, 0.81 W/kg and 1.29 W/kg respectively.
Digital Transmission System. Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-wor… (667 characters, open to read all)
Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory is 0.04 W/kg, 0.64 W/kg and 1.29 W/kg respectively.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Original Equipment — granted Aug 18, 2026
Grant 2 of 2 for this FCC ID.
Applications (3)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Part 15 Spread Spectrum Transmitter | Aug 18, 2026 | MiCOM Labs Pleasanton, CA, United States |
1 | Grant |
| Part 15 Low Power Communication Device Transmitter | Aug 18, 2026 | MiCOM Labs Pleasanton, CA, United States |
1 | Grant |
| PCS Licensed Transmitter | Aug 18, 2026 | MiCOM Labs Pleasanton, CA, United States |
29 | Grant |
Frequency bands (18)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 2402 – 2480 | 6.28 mW | 15C | — | — | CC |
| 704 – 711 | 149.28 mW | 27 | 0.014585 PM | 9M00G7D | — |
| 709 – 711 | 161.81 mW | 27 | 0.013341 PM | 9M00G7D | — |
| 819 | 134.9 mW | 90 | 0.010755 PM | 8M99G7D | — |
| 824.2 – 848.8 | 1.14551 W | 22H | 0.014825 PM | 246KGXW | — |
| 826.4 – 846.6 | 179.47 mW | 22H | 0.029818 PM | 4M16F9W | — |
| 829 – 844 | 149.28 mW | 22H | 0.008175 PM | 8M98G7D | — |
| 831.5 – 841.5 | 108.14 mW | 22H | 0.012546 PM | 13M4G7D | — |
| 1712.4 – 1752.6 | 143.55 mW | 27 | 0.013259 PM | 4M15F9W | — |
| 1720 – 1745 | 139.96 mW | 27 | 0.005673 PM | 18M0G7D | — |
| 1720 – 1770 | 140.6 mW | 27 | 0.008 PM | 17M9G7D | — |
| 1850.2 – 1907.6 | 729.46 mW | 24E | 0.013638 PM | 248KGXW | — |
| 1852.4 – 1907.6 | 176.2 mW | 24E | 0.011761 PM | 4M15F9W | — |
| 1860 – 1900 | 142.56 mW | 24E | 0.007854 PM | 17M9G7D | — |
| 1860 – 1905 | 142.89 mW | 24E | 0.014343 PM | 17M9G7D | — |
| 2510 – 2560 | 153.11 mW | 27 | 0.003979 PM | 17M9G7D | — |
| 3500 | 280.09 mW | 27 | 0.004286 PM | 97M6G7D | — |
| 13.56 | — | 15C | — | — | CC |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Part 15 Spread Spectrum Transmitter. Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific… (614 characters, open to read all)
Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory is 0.30 W/kg, 0.30 W/kg and 1.29 W/kg respectively.
PCS Licensed Transmitter. Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn … (797 characters, open to read all)
Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory is 0.99 W/kg, 0.99 W/kg and 1.29 W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Other devices by SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
All 36 FCC IDs of SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD.
Recent DTS devices
Digital Transmission System devices granted closest in time to 2ANMU-RT11.
All 18017 FCC IDs in class Digital Transmission System.
Recent PCB devices
PCS Licensed Transmitter devices granted closest in time to 2ANMU-RT11.
All 1088 FCC IDs in class PCS Licensed Transmitter.
Recent DXX devices
Part 15 Low Power Communication Device Transmitter devices granted closest in time to 2ANMU-RT11.
All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.
Recent DSS devices
Part 15 Spread Spectrum Transmitter devices granted closest in time to 2ANMU-RT11.
All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.
Recent NII devices
Unlicensed National Information Infrastructure TX devices granted closest in time to 2ANMU-RT11.
All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.