FCC ID lookup › SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD › 2ANMU-WP66
FCC ID 2ANMU-WP66
Smart phone
- Company
- SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD (grantee code 2ANMU, China)
- Product code
- WP66
- Latest grant
- Jul 13, 2026 — Change in Identification
- Equipment classes
- Digital Transmission System (DTS); PCS Licensed Transmitter held to ear (PCE); Part 15 Low Power Communication Device Transmitter (DXX); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
- Certified by
- MiCOM Labs
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Change in Identification — granted Jul 13, 2026
Applications (5)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Part 15 Low Power Communication Device Transmitter | Jul 13, 2026 | MiCOM Labs Pleasanton, CA, United States |
1 | Grant |
| PCS Licensed Transmitter held to ear | Jul 13, 2026 | MiCOM Labs Pleasanton, CA, United States |
28 | Grant |
| Part 15 Spread Spectrum Transmitter | Jul 13, 2026 | MiCOM Labs Pleasanton, CA, United States |
1 | Grant |
| Unlicensed National Information Infrastructure TX | Jul 13, 2026 | MiCOM Labs Pleasanton, CA, United States |
2 | Grant |
| Digital Transmission System | Jul 13, 2026 | MiCOM Labs Pleasanton, CA, United States |
2 | Grant |
Frequency bands (21)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 2402 – 2480 | 769 µW | 15C | — | — | CC |
| 2412 – 2462 | 58.479 mW | 15C | — | — | CC |
| 704 – 711 | 97.724 mW | 27 | 0.013181 PM | 8M98W7D | — |
| 709 – 711 | 112.202 mW | 27 | 0.013996 PM | 8M98G7D | — |
| 819 | 79.8 mW | 90 | 0.010855 PM | 8M99G7D | — |
| 824.2 – 848.8 | 1.90546 W | 22H | 0.016631 PM | 249KGXW | — |
| 826.4 – 846.6 | 284.446 mW | 22H | 0.023852 PM | 4M17F9W | — |
| 829 – 844 | 98.855 mW | 22H | 0.008454 PM | 8M98G7D | — |
| 831.5 – 841.5 | 81.1 mW | 22H | 0.012519 PM | 13M5G7D | — |
| 1712.4 – 1752.6 | 219.786 mW | 27 | 0.014396 PM | 4M16F9W | — |
| 1720 – 1745 | 92.683 mW | 27 | 0.005418 PM | 18M0G7D | — |
| 1720 – 1770 | 86.298 mW | 27 | 0.008133 PM | 17M9G7D | — |
| 1850.2 – 1909.8 | 1.21899 W | 24E | 0.01191 PM | 250KGXW | — |
| 1860 – 1900 | 94.406 mW | 24E | 0.007784 PM | 18M0G7D | — |
| 1860 – 1905 | 89.125 mW | 24E | 0.014343 PM | 18M0G7D | — |
| 2510 – 2560 | 101.391 mW | 27 | 0.00414 PM | 18M0G7D | — |
| 3500 | 141.906 mW | 27 | 0.008286 PM | 97M4G7D | — |
| 2402 – 2480 | 3.776 mW | 15C | — | — | CC |
| 13.56 | — | 15C | — | — | CC |
| 5180 – 5240 | 19.861 mW | 15E | — | — | CC |
| 5745 – 5825 | 15.276 mW | 15E | — | — | CC |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
PCS Licensed Transmitter held to ear. Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn … (815 characters, open to read all)
Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory is 0.79 W/kg, 1.32 W/kg, 1.32 W/kg and 1.42 W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.
Part 15 Spread Spectrum Transmitter. Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific… (632 characters, open to read all)
Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory is 0.13 W/kg, 0.07 W/kg, 0.07 W/kg and 1.42 W/kg respectively.
Unlicensed National Information Infrastructure TX. Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body… (688 characters, open to read all)
Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory is 0.28W/kg, 0.10 W/kg, 0.15 W/kg and 1.42 W/kg respectively.
Digital Transmission System. Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-wor… (684 characters, open to read all)
Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory is 0.36W/kg, 0.25 W/kg, 0.25 W/kg and 1.42 W/kg respectively.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Other devices by SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD
All 36 FCC IDs of SHENZHEN YUNJI INTELLIGENT TECHNOLOGY CO.,LTD.
Recent DTS devices
Digital Transmission System devices granted closest in time to 2ANMU-WP66.
All 18017 FCC IDs in class Digital Transmission System.
Recent PCE devices
PCS Licensed Transmitter held to ear devices granted closest in time to 2ANMU-WP66.
All 493 FCC IDs in class PCS Licensed Transmitter held to ear.
Recent DXX devices
Part 15 Low Power Communication Device Transmitter devices granted closest in time to 2ANMU-WP66.
All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.
Recent DSS devices
Part 15 Spread Spectrum Transmitter devices granted closest in time to 2ANMU-WP66.
All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.
Recent NII devices
Unlicensed National Information Infrastructure TX devices granted closest in time to 2ANMU-WP66.
All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.