FCC ID lookup › Hangzhou Sciener Smart Technology Co., Ltd. › 2AOVG-G4N
FCC ID 2AOVG-G4N
SMART LOCK GATEWAY G4N
- Company
- Hangzhou Sciener Smart Technology Co., Ltd. (grantee code 2AOVG, China)
- Product code
- G4N
- Latest grant
- Jul 15, 2026 — Original Equipment
- Equipment classes
- Digital Transmission System (DTS); Licensed Non-Broadcast Station Transmitter (TNB); PCS Licensed Transmitter (PCB)
- Certified by
- QAI LABORATORIES LTD
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Original Equipment — granted Jul 15, 2026
Grant 1 of 2 for this FCC ID.
Application (1)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Digital Transmission System | Jul 8, 2026 | QAI LABORATORIES LTD Burnaby, BC, Canada |
1 | Grant |
Frequency bands (1)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 2402 – 2480 | 1.7 mW | 15C | — | — | — |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Original Equipment — granted Jul 8, 2026
Grant 2 of 2 for this FCC ID.
Applications (2)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Licensed Non-Broadcast Station Transmitter | Jul 8, 2026 | QAI LABORATORIES LTD Burnaby, BC, Canada |
3 | Grant |
| PCS Licensed Transmitter | Jul 8, 2026 | QAI LABORATORIES LTD Burnaby, BC, Canada |
28 | Grant |
Frequency bands (19)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 699.7 – 715.3 | 143.2 mW | 27 | 2.5 PM | 1M10W7D | — |
| 704 – 711 | 163.7 mW | 27 | 2.5 PM | 9M02G7D | — |
| 782 | 173.8 mW | 27 | 2.5 PM | 9M02G7D | — |
| 824.7 – 848.3 | 150.3 mW | 22H | 2.5 PM | 1M09W7D | — |
| 824.7 – 848.5 | 112.7 mW | 22H | 2.5 PM | 1M09W7D | — |
| 829 – 844 | 161.1 mW | 22H | 2.5 PM | 9W01G7D | — |
| 831.5 – 841.5 | 121.9 mW | 22H | 2.5 PM | 13M5G7D | — |
| 1710.7 – 1754.3 | 189.2 mW | 27 | 2.5 PM | 1M10W7D | — |
| 1710.7 – 1779.3 | 208.9 mW | 27 | 2.5 PM | 1M10W7D | — |
| 1720 – 1745 | 211.8 mW | 27 | 2.5 PM | 18M0G7D | — |
| 1720 – 1770 | 227.5 mW | 27 | 2.5 PM | 18M0G7D | — |
| 1850.7 – 1914.3 | 279.9 mW | 24E | 2.5 PM | 1M10W7D | — |
| 1860 – 1900 | 349.9 mW | 24E | 2.5 PM | 18M0G7D | — |
| 1860 – 1905 | 327.3 mW | 24E | 2.5 PM | 18M0G7D | — |
| 2506 – 2680 | 272.3 mW | 27 | 2.5 PM | 18M0G7D | — |
| 2510 – 2560 | 375.8 mW | 27 | 2.5 PM | 18M0G7D | — |
| 2580 – 2610 | 247.7 mW | 27 | 2.5 PM | 18M0G7D | — |
| 814.7 – 823.3 | 115.6 mW | 90 | 2.5 PM | 1M10W7D | — |
| 819 | 123.9 mW | 90 | 2.5 PM | 8M99G7D | — |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Licensed Non-Broadcast Station Transmitter. Power output listed is ERP. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.
PCS Licensed Transmitter. Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Other devices by Hangzhou Sciener Smart Technology Co., Ltd.
Recent DTS devices
Digital Transmission System devices granted closest in time to 2AOVG-G4N.
All 18017 FCC IDs in class Digital Transmission System.
Recent TNB devices
Licensed Non-Broadcast Station Transmitter devices granted closest in time to 2AOVG-G4N.
All 274 FCC IDs in class Licensed Non-Broadcast Station Transmitter.
Recent PCB devices
PCS Licensed Transmitter devices granted closest in time to 2AOVG-G4N.