FCC Radar

FCC ID lookup › Shenzhen Gotron Electronic CO.,LTD. › 2AOWK-GR1001

FCC ID 2AOWK-GR1001

Smart Phone

Company
Shenzhen Gotron Electronic CO.,LTD. (grantee code 2AOWK, China)
Product code
GR1001
Latest grant
Apr 17, 2026 — Original Equipment
Equipment classes
Digital Transmission System (DTS); PCS Licensed Transmitter held to ear (PCE); Part 15 Class B Computing Device Peripheral (JBP); Part 15 Low Power Communication Device Transmitter (DXX); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
DERYCOM CERTIFICATION SERVICES, INC.
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted Apr 17, 2026

Applications (6)

Equipment classApplication datedTCBBandsFCC record
Part 15 Spread Spectrum Transmitter Apr 17, 2026 DERYCOM CERTIFICATION SERVICES, INC.
Glencoe, MN, United States
1 Grant
PCS Licensed Transmitter held to ear Apr 17, 2026 DERYCOM CERTIFICATION SERVICES, INC.
Glencoe, MN, United States
31 Grant
Unlicensed National Information Infrastructure TX Apr 17, 2026 DERYCOM CERTIFICATION SERVICES, INC.
Glencoe, MN, United States
3 Grant
Part 15 Low Power Communication Device Transmitter Apr 17, 2026 DERYCOM CERTIFICATION SERVICES, INC.
Glencoe, MN, United States
1 Grant
Part 15 Class B Computing Device Peripheral Apr 17, 2026 DERYCOM CERTIFICATION SERVICES, INC.
Glencoe, MN, United States
1 Grant
Digital Transmission System Apr 17, 2026 DERYCOM CERTIFICATION SERVICES, INC.
Glencoe, MN, United States
2 Grant

Frequency bands (28)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
2402 – 2480 1.7 mW 15C — — CC
2412 – 2462 112.2 mW 15C — — CC
— — 15B — — CC
701.5 – 713.5 57.1 mW 27 2.5 PM 4M51G7D —
704 – 711 56 mW 27 2.5 PM 9M00G7D —
706.5 – 713.5 57.3 mW 27 2.5 PM 4M51G7D —
709 – 711 55.6 mW 27 2.5 PM 8M97G7D —
824.2 – 848.8 620.9 mW 22H 2.5 PM 250KGXW —
826.4 – 846.6 63.8 mW 22H 2.5 PM 4M16F9W —
826.5 – 846.5 74 mW 22H 2.5 PM 4M52G7D —
829 – 844 72.1 mW 22H 2.5 PM 8M99G7D —
1712.4 – 1752.6 169.8 mW 27 2.5 PM 4M17F9W —
1712.5 – 1777.5 157.4 mW 27 2.5 PM 4M55W7D —
1715 – 1750 144.9 mW 27 2.5 PM 4M53W7D —
1720 – 1745 177.8 mW 27 2.5 PM 18M0G7D —
1720 – 1770 189.7 mW 27 2.5 PM 18M0G7D —
1850.2 – 1909.8 1.1015 W 24E 2.5 PM 248KGXW —
1852.4 – 1907.6 231.2 mW 24E 2.5 PM 4M18F9W —
1860 – 1900 228 mW 24E 2.5 PM 18M0G7D —
2503.5 – 2682.5 265.5 mW 27 2.5 PM 13M5W7D —
2505 – 2565 154.9 mW 27 2.5 PM 9M00W7D —
2510 – 2560 192.3 mW 27 2.5 PM 18M0G7D —
2510 – 2680 267.3 mW 27 2.5 PM 18M0G7D —
13.56 — 15C — — CC
5180 – 5240 25.9 mW 15E — — CC
5260 – 5320 25.5 mW 15E — — CC ND
5745 – 5825 25.4 mW 15E — — CC
2402 – 2480 2.2 mW 15C — — CC

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Part 15 Spread Spectrum Transmitter. Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-wor… (689 characters, open to read all)

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.09 W/kg, 0.02 W/kg and 0.59 W/kg respectively.

PCS Licensed Transmitter held to ear. Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn … (819 characters, open to read all)

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.17 W/kg, 0.53 W/kg and 0.59 W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

Unlicensed National Information Infrastructure TX. Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body… (693 characters, open to read all)

Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.21 W/kg, 0.07 W/kg and 0.59 W/kg respectively.

Digital Transmission System. Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-wor… (689 characters, open to read all)

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory and simultaneous transmission use conditions is 0.04 W/kg, 0.06 W/kg and 0.59 W/kg respectively.

History

Other devices by Shenzhen Gotron Electronic CO.,LTD.

All 11 FCC IDs of Shenzhen Gotron Electronic CO.,LTD..

Recent DTS devices

Digital Transmission System devices granted closest in time to 2AOWK-GR1001.

All 18017 FCC IDs in class Digital Transmission System.

Recent PCE devices

PCS Licensed Transmitter held to ear devices granted closest in time to 2AOWK-GR1001.

All 493 FCC IDs in class PCS Licensed Transmitter held to ear.

Recent JBP devices

Part 15 Class B Computing Device Peripheral devices granted closest in time to 2AOWK-GR1001.

All 609 FCC IDs in class Part 15 Class B Computing Device Peripheral.

Recent DXX devices

Part 15 Low Power Communication Device Transmitter devices granted closest in time to 2AOWK-GR1001.

All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to 2AOWK-GR1001.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to 2AOWK-GR1001.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.