FCC Radar

FCC ID lookup › Ugreen Group Limited › 2AQI5-CM787

FCC ID 2AQI5-CM787

AXE5400 Wi-Fi 6E High-Gain USB Adapter

Company
Ugreen Group Limited (grantee code 2AQI5, China)
Product code
CM787
Latest grant
Nov 27, 2025 — Original Equipment
Equipment classes
15E 6 GHz Low Power Indoor Client (6XD); Digital Transmission System (DTS); Unlicensed National Information Infrastructure TX (NII)
Certified by
Kiwa Nederland B.V.
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted Nov 27, 2025

Applications (3)

Equipment classApplication datedTCBBandsFCC record
Unlicensed National Information Infrastructure TX Nov 26, 2025 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
4 Grant
15E 6 GHz Low Power Indoor Client Nov 26, 2025 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
4 Grant
Digital Transmission System Nov 26, 2025 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant

Frequency bands (9)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
5180 – 5250 18 mW 15E — — CC MO
5250 – 5320 18 mW 15E — — CC MO ND
5500 – 5700 22 mW 15E — — CC MO ND
5745 – 5825 22 mW 15E — — CC MO
2412 – 2462 130 mW 15C — — CC MO
5955 – 6415 19 mW 15E — — CC EP MO
6435 – 6515 19 mW 15E — — CC EP MO
6535 – 6855 19 mW 15E — — CC EP MO
6875 – 7115 18 mW 15E — — CC EP MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Unlicensed National Information Infrastructure TX. Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configura… (681 characters, open to read all)

Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 5 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. This device supports 20 MHz, 40 MHz, 80 MHz and 160 MHz bandwidth modes. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are 0.80 W/kg and 1.55 W/kg, respectively.

15E 6 GHz Low Power Indoor Client. Power Output listed is Maximum EIRP. SAR compliance for body operating conditions is limited to the specific configurati… (829 characters, open to read all)

Power Output listed is Maximum EIRP. SAR compliance for body operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 5 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device supports 20 MHz, 40 MHz, 80 MHz and 160 MHz bandwidth modes. The highest reported SAR for stand-alone, simultaneous transmission exposure conditions and PD are 0.85 W/kg and 8.73 W/m2, respectively.

Digital Transmission System. Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configura… (664 characters, open to read all)

Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 5 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are 0.35 W/kg and 1.14 W/kg, respectively.

History

Other devices by Ugreen Group Limited

All 103 FCC IDs of Ugreen Group Limited.

Recent 6XD devices

15E 6 GHz Low Power Indoor Client devices granted closest in time to 2AQI5-CM787.

All 289 FCC IDs in class 15E 6 GHz Low Power Indoor Client.

Recent DTS devices

Digital Transmission System devices granted closest in time to 2AQI5-CM787.

All 18017 FCC IDs in class Digital Transmission System.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to 2AQI5-CM787.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.