FCC Radar

FCC ID lookup › ENLI INCORPORATION › 2AWKZ-MT7925B22M

FCC ID 2AWKZ-MT7925B22M

2TX 11be (WiFi7) BW160 + BT/BLE Combo Card

Company
ENLI INCORPORATION (grantee code 2AWKZ, Taiwan)
Product code
MT7925B22M
Latest grant
Oct 21, 2026 — Class II Permissive Change
Equipment classes
15E 6 GHZ Very Low Power Device (6VL); 15E 6 GHz Low Power Dual Client (6CD); Digital Transmission System (DTS); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
IIA Lab Services, LLC
FCC record
Grant of equipment authorization at apps.fcc.gov

Class II Permissive Change — granted Oct 21, 2026

Grant 1 of 2 for this FCC ID.

Applications (4)

Equipment classApplication datedTCBBandsFCC record
Part 15 Spread Spectrum Transmitter Oct 21, 2026 IIA Lab Services, LLC
Alachua, FL, United States
1 Grant
15E 6 GHz Low Power Dual Client Oct 21, 2026 IIA Lab Services, LLC
Alachua, FL, United States
3 Grant
Digital Transmission System Oct 21, 2026 IIA Lab Services, LLC
Alachua, FL, United States
2 Grant
Unlicensed National Information Infrastructure TX Oct 21, 2026 IIA Lab Services, LLC
Alachua, FL, United States
9 Grant

Frequency bands (15)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
5955 – 6415 997 mW 15E — — CC EP MO
5955 – 7115 104 mW 15E — — CC EP MO
6535 – 6855 990 mW 15E — — CC EP MO
2402 – 2480 20 mW 15C — — CC
5180 – 5250 239 mW 15E — — CC MO
5260 – 5320 223 mW 15E — — CC MO ND
5500 – 5720 210 mW 15E — — CC MO ND
5745 – 5825 618 mW 15E — — CC MO
5815 458 mW 15E — — CC EP MO
5835 689 mW 15E — — CC EP MO
5845 331 mW 15E — — CC EP MO
5855 985 mW 15E — — CC EP MO
5865 – 5885 631 mW 15E — — CC EP MO
2402 – 2480 20 mW 15C — — CC
2412 – 2472 401 mW 15C — — CC MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Part 15 Spread Spectrum Transmitter. Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described i… (974 characters, open to read all)

Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.24 W/kg and 1.03 W/kg, respectively. Class II Permissive Change: Authorizes portable use when integrated into the ONYX Healthcare Inc. Mobile Medical Assistant, Model ONYX-MD116T. The highest reported SAR values for body and simultaneous transmission use conditions are 0.17 W/kg and 1.51 W/kg, respectively.

15E 6 GHz Low Power Dual Client. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid… (1052 characters, open to read all)

This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.76 W/kg and 1.38 W/kg, respectively. This device has 20/40/80/160 MHz bandwidths. Class II Permissive Change: Authorizes portable use when integrated into the ONYX Healthcare Inc. Mobile Medical Assistant, Model ONYX-MD116T. The highest reported SAR values for body and simultaneous transmission use conditions are 0.21 W/kg and 1.51 W/kg, respectively. The highest reported power density is 2.51 W/m2.

Digital Transmission System. Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described i… (1012 characters, open to read all)

Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.62 W/kg and 1.41 W/kg, respectively. This device has 20/40 MHz bandwidths. Class II Permissive Change: Authorizes portable use when integrated into the ONYX Healthcare Inc. Mobile Medical Assistant, Model ONYX-MD116T. The highest reported SAR values for body and simultaneous transmission use conditions are 1.55 W/kg and 1.51 W/kg, respectively.

Unlicensed National Information Infrastructure TX. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid… (1035 characters, open to read all)

This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.79 W/kg and 1.41 W/kg, respectively. Device operation is intended for indoor use only. This device has 20/40/80/160 MHz bandwidths. Class II Permissive Change: Authorizes portable use when integrated into the ONYX Healthcare Inc. Mobile Medical Assistant, Model ONYX-MD116T. The highest reported SAR values for body and simultaneous transmission use conditions are 1.56 W/kg and 1.51 W/kg, respectively.

History

Change in Identification — granted Oct 13, 2026

Grant 2 of 2 for this FCC ID.

Applications (5)

Equipment classApplication datedTCBBandsFCC record
Part 15 Spread Spectrum Transmitter Oct 13, 2026 IIA Lab Services, LLC
Alachua, FL, United States
1 Grant
15E 6 GHZ Very Low Power Device Oct 13, 2026 IIA Lab Services, LLC
Alachua, FL, United States
1 Grant
Unlicensed National Information Infrastructure TX Oct 13, 2026 IIA Lab Services, LLC
Alachua, FL, United States
9 Grant
15E 6 GHz Low Power Dual Client Oct 13, 2026 IIA Lab Services, LLC
Alachua, FL, United States
3 Grant
Digital Transmission System Oct 13, 2026 IIA Lab Services, LLC
Alachua, FL, United States
2 Grant

Frequency bands (16)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
2402 – 2480 20 mW 15C — — CC
5180 – 5250 239 mW 15E — — CC MO
5260 – 5320 223 mW 15E — — CC MO ND
5500 – 5720 210 mW 15E — — CC MO ND
5745 – 5825 618 mW 15E — — CC MO
5815 458 mW 15E — — CC EP MO
5835 689 mW 15E — — CC EP MO
5845 331 mW 15E — — CC EP MO
5855 985 mW 15E — — CC EP MO
5865 – 5885 631 mW 15E — — CC EP MO
5955 – 6415 997 mW 15E — — CC EP MO
5955 – 7115 104 mW 15E — — CC EP MO
6535 – 6855 990 mW 15E — — CC EP MO
5955 – 7115 25 mW 15E — — CC EP MO
2402 – 2480 20 mW 15C — — CC
2412 – 2472 401 mW 15C — — CC MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Part 15 Spread Spectrum Transmitter. Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described i… (702 characters, open to read all)

Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.24 W/kg and 1.03 W/kg, respectively.

15E 6 GHZ Very Low Power Device. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators.… (813 characters, open to read all)

This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Besides, the SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR value for body use conditions is 0.24 W/kg. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Unlicensed National Information Infrastructure TX. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid… (763 characters, open to read all)

This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.79 W/kg and 1.41 W/kg, respectively. Device operation is intended for indoor use only. This device has 20/40/80/160 MHz bandwidths.

15E 6 GHz Low Power Dual Client. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid… (731 characters, open to read all)

This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.76 W/kg and 1.38 W/kg, respectively. This device has 20/40/80/160 MHz bandwidths.

Digital Transmission System. Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described i… (740 characters, open to read all)

Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.62 W/kg and 1.41 W/kg, respectively. This device has 20/40 MHz bandwidths.

History

Recent 6VL devices

15E 6 GHZ Very Low Power Device devices granted closest in time to 2AWKZ-MT7925B22M.

All 200 FCC IDs in class 15E 6 GHZ Very Low Power Device.

Recent 6CD devices

15E 6 GHz Low Power Dual Client devices granted closest in time to 2AWKZ-MT7925B22M.

All 215 FCC IDs in class 15E 6 GHz Low Power Dual Client.

Recent DTS devices

Digital Transmission System devices granted closest in time to 2AWKZ-MT7925B22M.

All 18017 FCC IDs in class Digital Transmission System.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to 2AWKZ-MT7925B22M.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to 2AWKZ-MT7925B22M.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.