FCC ID lookup › Arashi Vision Inc. › 2AWWH-CINSACHA
FCC ID 2AWWH-CINSACHA
Insta360 Luna Pro
- Company
- Arashi Vision Inc. (grantee code 2AWWH, China)
- Product code
- CINSACHA
- Latest grant
- May 8, 2026 — Class II Permissive Change
- Equipment classes
- Digital Transmission System (DTS); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
- Certified by
- IIA Lab Services, LLC
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Class II Permissive Change — granted May 8, 2026
Grant 1 of 2 for this FCC ID.
Applications (3)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Part 15 Spread Spectrum Transmitter | May 8, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
1 | Grant |
| Digital Transmission System | May 8, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
2 | Grant |
| Unlicensed National Information Infrastructure TX | May 8, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
4 | Grant |
Frequency bands (7)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 2402 – 2480 | 4 mW | 15C | — | — | CC |
| 2412 – 2462 | 295.8 mW | 15C | — | — | CC MO |
| 2402 – 2480 | 30.8 mW | 15C | — | — | CC |
| 5180 – 5240 | 47.2 mW | 15E | — | — | CC MO |
| 5260 – 5320 | 46.8 mW | 15E | — | — | CC MO ND |
| 5500 – 5700 | 46.9 mW | 15E | — | — | CC MO ND |
| 5745 – 5825 | 46.3 mW | 15E | — | — | CC MO |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Part 15 Spread Spectrum Transmitter. Output power listed is maximum combined conducted power. This device supports WLAN 802.11 b/g/n/a/ac/ax in SISO and MIMO… (797 characters, open to read all)
Output power listed is maximum combined conducted power. This device supports WLAN 802.11 b/g/n/a/ac/ax in SISO and MIMO (2x2) configurations with, where applicable, 20, 40 and 80MHz BW modes. SAR compliance for Limbs-worn operating configurations is limited to the specific configurations tested for this filing. Limbs-worn operations are must provide at least 0 cm separation between the device and the Limbs of the user. End-users must be informed of the Limbs-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for Limbs-worn (10-g extremity SAR) and simultaneous transmission use conditions is 0.51 W/kg and 0.88 W/kg at 10g tissue, respectively. Class II change : Removal of 1 camera Updated SAR at 10g Standalone 0.31W/ Kg Simultaneous SAR 0.88W/ Kg
Digital Transmission System. Output power listed is maximum combined conducted power. This device supports WLAN 802.11 b/g/n/a/ac/ax in SISO and MIMO… (798 characters, open to read all)
Output power listed is maximum combined conducted power. This device supports WLAN 802.11 b/g/n/a/ac/ax in SISO and MIMO (2x2) configurations with, where applicable, 20, 40 and 80MHz BW modes. SAR compliance for Limbs-worn operating configurations is limited to the specific configurations tested for this filing. Limbs-worn operations are must provide at least 0 cm separation between the device and the Limbs of the user. End-users must be informed of the Limbs-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for Limbs-worn (10-g extremity SAR) and simultaneous transmission use conditions is 0.51 W/kg and 0.88 W/kg at 10g tissue, respectively. Class II Change : Removal of 1 camera. Updated SAR at 10g Standalone 0.51W/ Kg Simultaneous SAR 0.88W/ Kg
Unlicensed National Information Infrastructure TX. Output power listed is maximum combined conducted power. This device supports WLAN 802.11 b/g/n/a/ac/ax in SISO and MIMO… (913 characters, open to read all)
Output power listed is maximum combined conducted power. This device supports WLAN 802.11 b/g/n/a/ac/ax in SISO and MIMO (2x2) configurations with, where applicable, 20, 40 and 80MHz BW modes. For Dynamic Frequency Selection (DFS) relevant bands, the device operates as a client without radar detection only. SAR compliance for Limbs-worn operating configurations is limited to the specific configurations tested for this filing. Limbs-worn operations are must provide at least 0 cm separation between the device and the Limbs of the user. End-users must be informed of the Limbs-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for Limbs-worn (10-g extremity SAR) and simultaneous transmission use conditions is 0.80 W/kg and 0.88 W/kg at 10g tissue, respectively. Class II change : Removal of 1 camera Updated SAR at 10g Standalone 0.51W/ Kg Simultaneous SAR 0.88W/ Kg
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Change in Identification — granted Apr 28, 2026
Grant 2 of 2 for this FCC ID.
Applications (3)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Unlicensed National Information Infrastructure TX | Apr 28, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
4 | Grant |
| Digital Transmission System | Apr 28, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
2 | Grant |
| Part 15 Spread Spectrum Transmitter | Apr 28, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
1 | Grant |
Frequency bands (7)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 5180 – 5240 | 47.2 mW | 15E | — | — | CC MO |
| 5260 – 5320 | 46.8 mW | 15E | — | — | CC MO ND |
| 5500 – 5700 | 46.9 mW | 15E | — | — | CC MO ND |
| 5745 – 5825 | 46.3 mW | 15E | — | — | CC MO |
| 2402 – 2480 | 30.8 mW | 15C | — | — | CC |
| 2402 – 2480 | 4 mW | 15C | — | — | CC |
| 2412 – 2462 | 295.8 mW | 15C | — | — | CC MO |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Unlicensed National Information Infrastructure TX. Output power listed is maximum combined conducted power. This device supports WLAN 802.11 b/g/n/a/ac/ax in SISO and MIMO… (808 characters, open to read all)
Output power listed is maximum combined conducted power. This device supports WLAN 802.11 b/g/n/a/ac/ax in SISO and MIMO (2x2) configurations with, where applicable, 20, 40 and 80MHz BW modes. For Dynamic Frequency Selection (DFS) relevant bands, the device operates as a client without radar detection only. SAR compliance for Limbs-worn operating configurations is limited to the specific configurations tested for this filing. Limbs-worn operations are must provide at least 0 cm separation between the device and the Limbs of the user. End-users must be informed of the Limbs-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for Limbs-worn (10-g extremity SAR) and simultaneous transmission use conditions is 0.80 W/kg and 0.88 W/kg at 10g tissue, respectively.
Digital Transmission System. Output power listed is maximum combined conducted power. This device supports WLAN 802.11 b/g/n/a/ac/ax in SISO and MIMO… (692 characters, open to read all)
Output power listed is maximum combined conducted power. This device supports WLAN 802.11 b/g/n/a/ac/ax in SISO and MIMO (2x2) configurations with, where applicable, 20, 40 and 80MHz BW modes. SAR compliance for Limbs-worn operating configurations is limited to the specific configurations tested for this filing. Limbs-worn operations are must provide at least 0 cm separation between the device and the Limbs of the user. End-users must be informed of the Limbs-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for Limbs-worn (10-g extremity SAR) and simultaneous transmission use conditions is 0.51 W/kg and 0.88 W/kg at 10g tissue, respectively.
Part 15 Spread Spectrum Transmitter. Output power listed is conducted power. SAR compliance for Limbs-worn operating configurations is limited to the specific configurations tested for this filing. Limbs-worn operations are must provide at least 0 cm separation between the device and the Limbs of the user. End-users must be informed of the Limbs-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for Limbs-worn (10-g extremity SAR) and simultaneous transmission use conditions is 0.31 W/kg and 0.88 W/kg at 10g tissue, respectively.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Other devices by Arashi Vision Inc.
All 20 FCC IDs of Arashi Vision Inc..
Recent DTS devices
Digital Transmission System devices granted closest in time to 2AWWH-CINSACHA.
All 18017 FCC IDs in class Digital Transmission System.
Recent DSS devices
Part 15 Spread Spectrum Transmitter devices granted closest in time to 2AWWH-CINSACHA.
All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.
Recent NII devices
Unlicensed National Information Infrastructure TX devices granted closest in time to 2AWWH-CINSACHA.
All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.