FCC Radar

FCC ID lookup › WOM ASIA CO., LTD › 2AXAMMT7922A

FCC ID 2AXAMMT7922A

Industrial Gigabit AX Wi-Fi 6 Wireless Module

Company
WOM ASIA CO., LTD (grantee code 2AXAM, Taiwan)
Product code
MT7922A
Latest grant
Jul 30, 2026 — Change in Identification
Equipment classes
15E 6 GHZ Very Low Power Device (6VL); 15E 6 GHz Low Power Dual Client (6CD); 15E 6 GHz Low Power Indoor Client (6XD); Digital Transmission System (DTS); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
Bay Area Compliance Laboratories Corp.
FCC record
Grant of equipment authorization at apps.fcc.gov

Change in Identification — granted Jul 30, 2026

Applications (6)

Equipment classApplication datedTCBBandsFCC record
15E 6 GHz Low Power Indoor Client Jun 9, 2026 Bay Area Compliance Laboratories Corp.
Sunnyvale, CA, United States
1 Grant
15E 6 GHz Low Power Dual Client Jun 9, 2026 Bay Area Compliance Laboratories Corp.
Sunnyvale, CA, United States
3 Grant
15E 6 GHZ Very Low Power Device Jun 9, 2026 Bay Area Compliance Laboratories Corp.
Sunnyvale, CA, United States
1 Grant
Digital Transmission System Jul 27, 2026 Bay Area Compliance Laboratories Corp.
Sunnyvale, CA, United States
2 Grant
Part 15 Spread Spectrum Transmitter Jul 27, 2026 Bay Area Compliance Laboratories Corp.
Sunnyvale, CA, United States
1 Grant
Unlicensed National Information Infrastructure TX Jul 27, 2026 Bay Area Compliance Laboratories Corp.
Sunnyvale, CA, United States
4 Grant

Frequency bands (12)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
2402 – 2480 22 mW 15C — — CC
2412 – 2472 769 mW 15C — — CC MO
5955 – 6415 965 mW 15E — — CC EP MO
5955 – 7115 55 mW 15E — — CC EP MO
6535 – 6855 959 mW 15E — — CC EP MO
5955 – 7115 55 mW 15E — — CC MO
5955 – 7115 25 mW 15E — — CC EP MO
2402 – 2480 23 mW 15C — — CC
5180 – 5240 198 mW 15E — — CC MO
5250 – 5320 195 mW 15E — — CC MO ND
5500 – 5720 208 mW 15E — — CC MO ND
5745 – 5825 251 mW 15E — — CC MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

15E 6 GHz Low Power Indoor Client. Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described i… (911 characters, open to read all)

Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.42 W/kg and 0.68 W/kg, respectively. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device has 20/40/80/160 MHz bandwidths.

15E 6 GHz Low Power Dual Client. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators.… (824 characters, open to read all)

This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80/160 MHz bandwidths. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.79 W/kg and 1.05 W/kg, respectively.

15E 6 GHZ Very Low Power Device. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators.… (824 characters, open to read all)

This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80/160 MHz bandwidths. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.21 W/kg and 1.05 W/kg, respectively.

Digital Transmission System. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (1265 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidths. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.29 W/kg and 0.55 W/kg, respectively. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.34 W/kg and 0.77 W/kg, respectively.

Part 15 Spread Spectrum Transmitter. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (1227 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.26 W/kg and 0.60 W/kg, respectively. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.43 W/kg and 1.19 W/kg, respectively.

Unlicensed National Information Infrastructure TX. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (1272 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80/160 MHz bandwidths. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.34 W/kg and 0.60 W/kg, respectively. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.76 W/kg and 1.19 W/kg, respectively.

History

Other devices by WOM ASIA CO., LTD

Recent 6VL devices

15E 6 GHZ Very Low Power Device devices granted closest in time to 2AXAMMT7922A.

All 200 FCC IDs in class 15E 6 GHZ Very Low Power Device.

Recent 6CD devices

15E 6 GHz Low Power Dual Client devices granted closest in time to 2AXAMMT7922A.

All 215 FCC IDs in class 15E 6 GHz Low Power Dual Client.

Recent 6XD devices

15E 6 GHz Low Power Indoor Client devices granted closest in time to 2AXAMMT7922A.

All 289 FCC IDs in class 15E 6 GHz Low Power Indoor Client.

Recent DTS devices

Digital Transmission System devices granted closest in time to 2AXAMMT7922A.

All 18017 FCC IDs in class Digital Transmission System.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to 2AXAMMT7922A.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to 2AXAMMT7922A.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.