FCC ID lookup › M&M Electronics, S.A. › 2BLU9-QT11AVHEM
FCC ID 2BLU9-QT11AVHEM
Tablet PC
- Company
- M&M Electronics, S.A. (grantee code 2BLU9, Panama)
- Product code
- QT11AVHEM
- Latest grant
- Nov 25, 2025 — Original Equipment
- Equipment classes
- Digital Transmission System (DTS); PCS Licensed Transmitter (PCB); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
- Certified by
- MiCOM Labs
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Original Equipment — granted Nov 25, 2025
Grant 1 of 2 for this FCC ID.
Applications (2)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Digital Transmission System | Nov 25, 2025 | MiCOM Labs Pleasanton, CA, United States |
2 | Grant |
| Unlicensed National Information Infrastructure TX | Nov 25, 2025 | MiCOM Labs Pleasanton, CA, United States |
4 | Grant |
Frequency bands (6)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 2402 – 2480 | 1.01 mW | 15C | — | — | CC |
| 2412 – 2462 | 25.47 mW | 15C | — | — | CC |
| 5180 – 5240 | 18.16 mW | 15E | — | — | CC |
| 5260 – 5320 | 22.96 mW | 15E | — | — | CC ND |
| 5500 – 5700 | 23.33 mW | 15E | — | — | CC ND |
| 5745 – 5825 | 22.18 mW | 15E | — | — | CC |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Digital Transmission System. Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-wor… (667 characters, open to read all)
Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory is 0.14 W/kg, 0.14 W/kg and 1.34 W/kg respectively.
Unlicensed National Information Infrastructure TX. Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body… (671 characters, open to read all)
Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory is 0.44 W/kg, 0.44 W/kg and 1.34 W/kg respectively.
History
- Oct 20, 2026: grant first recorded in FCC Radar.
Original Equipment — granted Nov 24, 2025
Grant 2 of 2 for this FCC ID.
Applications (2)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| PCS Licensed Transmitter | Nov 24, 2025 | MiCOM Labs Pleasanton, CA, United States |
8 | Grant |
| Part 15 Spread Spectrum Transmitter | Nov 24, 2025 | MiCOM Labs Pleasanton, CA, United States |
1 | Grant |
Frequency bands (7)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 2402 – 2480 | 3.01 mW | 15C | — | — | CC |
| 824.2 – 848.8 | 1.59221 W | 22H | 0.011119 PM | 246KGXW | — |
| 826.4 – 846.6 | 232.27 mW | 22H | 0.022812 PM | 4M17F9W | — |
| 1720 – 1745 | 78.7 mW | 27 | 0.005356 PM | 18M0G7D | — |
| 1850.2 – 1909.8 | 897.43 mW | 24E | 0.012691 PM | 249KGXW | — |
| 1852.4 – 1907.6 | 236.05 mW | 24E | 0.011787 PM | 4M16F9W | — |
| 2510 – 2560 | 86 mW | 27 | 0.004119 PM | 17M9G7D | — |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
PCS Licensed Transmitter. Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn … (796 characters, open to read all)
Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory is 0.90W/kg, 0.90 W/kg and 1.34 W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.
Part 15 Spread Spectrum Transmitter. Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific… (614 characters, open to read all)
Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory is 0.13 W/kg, 0.13 W/kg and 1.34 W/kg respectively.
History
- Oct 20, 2026: grant first recorded in FCC Radar.
Other devices by M&M Electronics, S.A.
All 15 FCC IDs of M&M Electronics, S.A..
Recent DTS devices
Digital Transmission System devices granted closest in time to 2BLU9-QT11AVHEM.
All 18017 FCC IDs in class Digital Transmission System.
Recent PCB devices
PCS Licensed Transmitter devices granted closest in time to 2BLU9-QT11AVHEM.
All 1088 FCC IDs in class PCS Licensed Transmitter.
Recent DSS devices
Part 15 Spread Spectrum Transmitter devices granted closest in time to 2BLU9-QT11AVHEM.
All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.
Recent NII devices
Unlicensed National Information Infrastructure TX devices granted closest in time to 2BLU9-QT11AVHEM.
All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.