FCC Radar

FCC ID lookup › M&M Electronics, S.A. › 2BLU9-QT9AVHEQ

FCC ID 2BLU9-QT9AVHEQ

Tablet PC

Company
M&M Electronics, S.A. (grantee code 2BLU9, Panama)
Product code
QT9AVHEQ
Latest grant
Nov 20, 2025 — Original Equipment
Equipment classes
Digital Transmission System (DTS); PCS Licensed Transmitter (PCB); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
MiCOM Labs
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted Nov 20, 2025

Applications (4)

Equipment classApplication datedTCBBandsFCC record
PCS Licensed Transmitter Nov 20, 2025 MiCOM Labs
Pleasanton, CA, United States
8 Grant
Part 15 Spread Spectrum Transmitter Nov 20, 2025 MiCOM Labs
Pleasanton, CA, United States
1 Grant
Digital Transmission System Nov 20, 2025 MiCOM Labs
Pleasanton, CA, United States
2 Grant
Unlicensed National Information Infrastructure TX Nov 20, 2025 MiCOM Labs
Pleasanton, CA, United States
4 Grant

Frequency bands (13)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
2402 – 2480 1.148 mW 15C — — CC
2412 – 2462 34.277 mW 15C — — CC
2402 – 2480 6.124 mW 15C — — CC
824.2 – 848.8 1.24738 W 22H 0.016392 PM 250KGXW —
826.4 – 846.6 163.682 mW 22H 0.025407 PM 4M18F9W —
1720 – 1745 93.756 mW 27 0.00528 PM 18M1G7D —
1850.2 – 1909.8 781.628 mW 24E 0.013191 PM 250KGXW —
1852.4 – 1907.6 185.78 mW 24E 0.012133 PM 4M34F9W —
2510 – 2560 102.565 mW 27 0.003896 PM 18M0G7D —
5180 – 5240 22.08 mW 15E — — CC
5260 – 5320 18.967 mW 15E — — CC ND
5500 – 5700 23.442 mW 15E — — CC ND
5745 – 5825 21.232 mW 15E — — CC

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

PCS Licensed Transmitter. Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn … (666 characters, open to read all)

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory are 0.75 W/kg, 0.75 W/kg and 1.14 W/kg respectively.

Part 15 Spread Spectrum Transmitter. Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to … (627 characters, open to read all)

Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory are 0.27 W/kg, 0.27 W/kg and 1.02 W/kg respectively.

Digital Transmission System. Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance … (680 characters, open to read all)

Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory are 0.49 W/kg, 0.49 W/kg and 0.92 W/kg respectively.

Unlicensed National Information Infrastructure TX. Power listed is the maximum conducted output power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR complia… (684 characters, open to read all)

Power listed is the maximum conducted output power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn, hotspot and simultaneous SAR accessory are 0.72 W/kg, 0.72 W/kg and 1.14 W/kg respectively.

History

Other devices by M&M Electronics, S.A.

All 15 FCC IDs of M&M Electronics, S.A..

Recent DTS devices

Digital Transmission System devices granted closest in time to 2BLU9-QT9AVHEQ.

All 18017 FCC IDs in class Digital Transmission System.

Recent PCB devices

PCS Licensed Transmitter devices granted closest in time to 2BLU9-QT9AVHEQ.

All 1088 FCC IDs in class PCS Licensed Transmitter.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to 2BLU9-QT9AVHEQ.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to 2BLU9-QT9AVHEQ.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.