FCC Radar

FCC ID lookup › UROVO PTE. LIMITED › 2BQURK388PRO

FCC ID 2BQURK388PRO

Mobile Labeling Printer

Company
UROVO PTE. LIMITED (grantee code 2BQUR, Singapore)
Product code
K388PRO
Latest grant
Feb 25, 2026 — Original Equipment
Equipment classes
15E 6 GHz Low Power Indoor Client (6XD); Digital Transmission System (DTS); Licensed Non-Broadcast Transmitter Worn on Body (TNT); Part 15 Low Power Communication Device Transmitter (DXX); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
NMi TESTLAB GmbH
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted Feb 25, 2026

Applications (6)

Equipment classApplication datedTCBBandsFCC record
15E 6 GHz Low Power Indoor Client Feb 11, 2026 NMi TESTLAB GmbH
32825 Blomberg,, Germany
1 Grant
Part 15 Low Power Communication Device Transmitter Feb 11, 2026 NMi TESTLAB GmbH
32825 Blomberg,, Germany
1 Grant
Digital Transmission System Feb 11, 2026 NMi TESTLAB GmbH
32825 Blomberg,, Germany
2 Grant
Part 15 Spread Spectrum Transmitter Feb 11, 2026 NMi TESTLAB GmbH
32825 Blomberg,, Germany
2 Grant
Unlicensed National Information Infrastructure TX Feb 11, 2026 NMi TESTLAB GmbH
32825 Blomberg,, Germany
4 Grant
Licensed Non-Broadcast Transmitter Worn on Body Feb 11, 2026 NMi TESTLAB GmbH
32825 Blomberg,, Germany
2 Grant

Frequency bands (11)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
829 – 844 165 mW 22H 0.024 PM 8M97G7D —
2402 – 2480 8.28 mW 15C — — CC
2412 – 2472 722.97 mW 15C — — CC MO
5180 – 5240 104.58 mW 15E — — CC MO
5260 – 5320 111.2 mW 15E — — CC MO
5500 – 5720 123.54 mW 15E — — CC MO
5745 – 5825 106.54 mW 15E — — CC MO
13.56 — 15C — — CC
902.75 – 927.25 756.83 mW 15C — — CC
2402 – 2480 8.02 mW 15C — — CC
5955 – 7115 25.88 mW 15E — — CC EP MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

15E 6 GHz Low Power Indoor Client. Output power is maximum EIRP. This device supports IEEE 802.11 ax 20, 40 and 80 MHz channel bandwidths. This device has … (655 characters, open to read all)

Output power is maximum EIRP. This device supports IEEE 802.11 ax 20, 40 and 80 MHz channel bandwidths. This device has integrated 6XD, DSS, DTS, DXX, NII and PCT transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. The highest reported SAR value for body-worn accessory use condition is 0.42 W/kg at 1g tissues. The highest reported power density is 0.31 mW/cm2 Product specific SAR at 10-gram tissue is 0.30 W/kg.

Part 15 Low Power Communication Device Transmitter. This device has integrated 6XD, DSS, DTS, DXX, NII and PCT transmitters certified under the same FCC ID.
Digital Transmission System. Output power is maximum peak conducted. This device supports IEEE 802.11 b/g/n20/ax20 MHz channel bandwidths. This devic… (718 characters, open to read all)

Output power is maximum peak conducted. This device supports IEEE 802.11 b/g/n20/ax20 MHz channel bandwidths. This device has integrated 6XD, DSS, DTS, DXX, NII and PCT transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt- clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value for body-worn accessory use condition is 0.39 W/kg at 1g tissues. Product specific SAR at 10-gram tissue is 0.74 W/kg.

Part 15 Spread Spectrum Transmitter. Output power is maximum peak conducted. This device has integrated 6XD, DSS, DTS, DXX, NII and PCT transmitters certifie… (680 characters, open to read all)

Output power is maximum peak conducted. This device has integrated 6XD, DSS, DTS, DXX, NII and PCT transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory and hotspot use conditions are <0.10 W/kg, and <0.10 W/kg, respectively. Product specific SAR at 10-gram tissue is <0.10 W/kg.

Unlicensed National Information Infrastructure TX. Output power is maximum average conducted. This device supports IEEE 802.11 a/n/ac/ax 20, 40 and 80 MHz channel bandwidt… (625 characters, open to read all)

Output power is maximum average conducted. This device supports IEEE 802.11 a/n/ac/ax 20, 40 and 80 MHz channel bandwidths. This device has integrated 6XD, DSS, DTS, DXX, NII and PCT transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. The highest reported SAR value for body-worn accessory use condition is 1.26 W/kg at 1g tissues. Product specific SAR at 10-gram tissue is 1.68 W/kg.

Licensed Non-Broadcast Transmitter Worn on Body. Output power listed for LTE Band 5 is maximum ERP It supports LTE (QPSK, 16QAM, 64QAM). LTE B5 Channel Bandwidth (1.4/3/… (868 characters, open to read all)

Output power listed for LTE Band 5 is maximum ERP It supports LTE (QPSK, 16QAM, 64QAM). LTE B5 Channel Bandwidth (1.4/3/5/10 MHz) for LTE B5 This device contains functions that are not operational in U.S. Territories; this filing is only applicable for U.S. operations. This device has integrated 6XD, DSS, DTS, DXX, NII and PCT transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory and hotspot use conditions are 0.33 W/kg, and 0.33 W/kg at 1g tissues, respectively.

History

Other devices by UROVO PTE. LIMITED

Recent 6XD devices

15E 6 GHz Low Power Indoor Client devices granted closest in time to 2BQURK388PRO.

All 289 FCC IDs in class 15E 6 GHz Low Power Indoor Client.

Recent DTS devices

Digital Transmission System devices granted closest in time to 2BQURK388PRO.

All 18017 FCC IDs in class Digital Transmission System.

Recent TNT devices

Licensed Non-Broadcast Transmitter Worn on Body devices granted closest in time to 2BQURK388PRO.

All 30 FCC IDs in class Licensed Non-Broadcast Transmitter Worn on Body.

Recent DXX devices

Part 15 Low Power Communication Device Transmitter devices granted closest in time to 2BQURK388PRO.

All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to 2BQURK388PRO.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to 2BQURK388PRO.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.