FCC ID lookup › Guangzhou Licon Intelligent Technology Co., LTD › 2BVFG-WLL-A100
FCC ID 2BVFG-WLL-A100
Cash register
- Company
- Guangzhou Licon Intelligent Technology Co., LTD (grantee code 2BVFG, China)
- Product code
- WLL-A100
- Latest grant
- Apr 24, 2026 — Original Equipment
- Equipment classes
- Digital Transmission System (DTS); Unlicensed National Information Infrastructure TX (NII)
- Certified by
- KL-Certification GmbH
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Original Equipment — granted Apr 24, 2026
Applications (2)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Unlicensed National Information Infrastructure TX | Apr 24, 2026 | KL-Certification GmbH St. Ingbert, Germany |
2 | Grant |
| Digital Transmission System | Apr 24, 2026 | KL-Certification GmbH St. Ingbert, Germany |
1 | Grant |
Frequency bands (3)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 5180 – 5240 | 40.3 mW | 15E | — | — | CC |
| 5745 – 5825 | 55.7 mW | 15E | — | — | CC |
| 2412 – 2462 | 41.3 mW | 15C | — | — | CC |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Unlicensed National Information Infrastructure TX. Output Power listed is average conducted. This device supports 802.11a, 802.11n and 802.11ac with a 20 MHz, 40MHz and 80 MHz bandwidth mode. For body worn operation, this device has been tested and meets FCC RF exposure guidelines when used at a minimum distance of 0 mm from the body. The highest reported SAR for body-worn and simultaneous transmission use conditions are 0.45 W/kg, and 0.66 W/kg, respectively.
Digital Transmission System. Output Power listed is average conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. For body worn operation, this device has been tested and meets FCC RF exposure guidelines when used at a minimum distance of 0 mm from the body. The highest reported SAR for body-worn and simultaneous transmission use conditions are 0.21 W/kg, and 0.66 W/kg, respectively.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Recent DTS devices
Digital Transmission System devices granted closest in time to 2BVFG-WLL-A100.
All 18017 FCC IDs in class Digital Transmission System.
Recent NII devices
Unlicensed National Information Infrastructure TX devices granted closest in time to 2BVFG-WLL-A100.
All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.