FCC Radar

FCC ID lookup › MediBioSense Ltd › 2BWTH-IWT1

FCC ID 2BWTH-IWT1

Infinity Watch

Company
MediBioSense Ltd (grantee code 2BWTH, United Kingdom)
Product code
IWT1
Latest grant
Oct 31, 2026 — Original Equipment
Equipment classes
Digital Transmission System (DTS); PCS Licensed Transmitter worn on body (PCT); Part 15 Low Power Communication Device Transmitter (DXX); Part 15 Spread Spectrum Transmitter (DSS)
Certified by
QAI LABORATORIES LTD
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted Oct 31, 2026

Applications (4)

Equipment classApplication datedTCBBandsFCC record
Digital Transmission System Oct 30, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
2 Grant
PCS Licensed Transmitter worn on body Oct 30, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
22 Grant
Part 15 Low Power Communication Device Transmitter Oct 30, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
1 Grant
Part 15 Spread Spectrum Transmitter Nov 2, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
1 Grant

Frequency bands (20)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
13.56 — 15C — — CC
824.2 – 824.8 2.9242 W 22H 2.5 PM 246KGXW —
824.7 – 848.3 291.7 mW 22H 2.5 PM 1M08G7D —
825.5 – 847.5 265.5 mW 22H 2.5 PM 2M69W7D —
829 – 844 285.1 mW 22H 2.5 PM 8M99G7D —
1715 – 1750 595.7 mW 27 2.5 PM 8M99W7D —
1717.5 – 1747.5 673 mW 27 2.5 PM 13M5G7D —
1720 – 1745 547 mW 27 2.5 PM 18M0G7D —
1850.7 – 1909.3 580.8 mW 24E 2.5 PM 1M08G7D —
1851.5 – 1908.5 515.2 mW 24E 2.5 PM 2M69W7D —
1852.4 – 1907.6 422.7 mW 24E 2.5 PM 4M17F9W —
1860 – 1900 476.4 mW 24E 2.5 PM 18M0G7D —
2305 – 2395 666.8 mW 27 2.5 PM 9M02G7D —
2310 – 2390 645.7 mW 27 2.5 PM 18M0G7D —
2572.5 – 2617.5 490.9 mW 27 2.5 PM 4M49G7D —
2577.5 – 2612.5 425.6 mW 27 2.5 PM 13M4W7D —
2580 – 2610 462.4 mW 27 2.5 PM 17M9G7D —
2402 – 2480 6.73 mW 15C — — CC
2402 – 2480 2.03 mW 15C — — CC
2412 – 2462 36.31 mW 15C — — CC

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Digital Transmission System. Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-wor… (940 characters, open to read all)

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the face of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for face accessory and simultaneous transmission use conditions is 0.11 W/kg and 0.80 W/kg respectively. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for extremity is 4.0 W/kg. The evaluation distance for extremity is 0 mm. The highest reported SAR for extremity and simultaneous transmission use conditions are 0.21 W/kg and 0.86 W/kg respectively.

PCS Licensed Transmitter worn on body. Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn … (938 characters, open to read all)

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the face of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for face accessory and simultaneous transmission use conditions is 0.41 W/kg and 0.80 W/kg respectively. FCC RF Exposure Information and Statement that the SAR limit of USA (FCC) for extremity is 4.0 W/kg. The evaluation distance for extremity is 0 mm. The highest reported SAR for extremity and simultaneous transmission use conditions are 0.60 W/kg and 0.86 W/kg respectively.

Part 15 Spread Spectrum Transmitter. Output power listed is conducted power.

History

Recent DTS devices

Digital Transmission System devices granted closest in time to 2BWTH-IWT1.

All 18017 FCC IDs in class Digital Transmission System.

Recent PCT devices

PCS Licensed Transmitter worn on body devices granted closest in time to 2BWTH-IWT1.

All 113 FCC IDs in class PCS Licensed Transmitter worn on body.

Recent DXX devices

Part 15 Low Power Communication Device Transmitter devices granted closest in time to 2BWTH-IWT1.

All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to 2BWTH-IWT1.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.