FCC ID lookup › Extreme Networks, Inc. › QXO-AP5060
FCC ID QXO-AP5060
Access Point
- Company
- Extreme Networks, Inc. (grantee code QXO, United States)
- Product code
- AP5060
- Latest grant
- May 20, 2026 — Class II Permissive Change
- Equipment classes
- 15E 6 GHz Standard Power Access Point (6SD); Digital Transmission System (DTS); Unlicensed National Information Infrastructure TX (NII)
- Certified by
- IIA Lab Services, LLC
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Class II Permissive Change — granted May 20, 2026
Grant 1 of 2 for this FCC ID.
Applications (2)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| 15E 6 GHz Standard Power Access Point | May 5, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
2 | Grant |
| Unlicensed National Information Infrastructure TX | May 5, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
4 | Grant |
Frequency bands (6)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 5955 – 6415 | 3.963 W | 15E | — | — | CC EP MO |
| 6535 – 6855 | 3.963 W | 15E | — | — | CC EP MO |
| 5180 – 5250 | 643 mW | 15E | — | — | CC MO |
| 5250 – 5320 | 248 mW | 15E | — | — | CC MO ND |
| 5500 – 5720 | 248 mW | 15E | — | — | CC MO ND |
| 5745 – 5825 | 830 mW | 15E | — | — | CC MO |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
15E 6 GHz Standard Power Access Point. Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. Profess… (1209 characters, open to read all)
Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. Professional installation required. For pole or wall mount installations, this device must be installed to provide a separation distance of at least 40 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. For under-seat or floor installations (model AP5060U only), RF exposure compliance for body exposure (under seat) configurations is limited installations establishing a minimum separation distance of 25 mm, as described in this filing. The highest reported SAR values for body, simultaneous transmission and product-specific (10g extremity SAR) use conditions are 0.15 W/kg, 1.53 W/kg and 0.35 W/kg, respectively. The highest reported power density is 6.70 W/m2 Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80, 160 and 320 MHz bandwidth modes. C2PC to add U-Nii-2A and U-Nii-2C bands, add 160MHz, and add 5G/6G MRU and Puncturing to device via Factory installed firmware.
Unlicensed National Information Infrastructure TX. Output Power listed is the maximum combined conducted output power. Professional installation required. For pole or wall… (987 characters, open to read all)
Output Power listed is the maximum combined conducted output power. Professional installation required. For pole or wall mount installations, this device must be installed to provide a separation distance of at least 40 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. For under-seat or floor installations (model AP5060U only), RF exposure compliance for body exposure (under seat) configurations is limited installations establishing a minimum separation distance of 25 mm, as described in this filing. The highest reported SAR values for body, simultaneous transmission and product-specific (10g extremity SAR) use conditions are 0.68 W/kg, 1.53 W/kg and 1.60 W/kg, respectively. This device supports 20, 40, 80, and 160 MHz bandwidth modes. C2PC to add U-Nii-2A and U-Nii-2C bands, add 160MHz, and add 5G/6G MRU and Puncturing to device via Factory installed firmware.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Original Equipment — granted Feb 18, 2026
Grant 2 of 2 for this FCC ID.
Applications (3)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Digital Transmission System | Feb 3, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
3 | Grant |
| Unlicensed National Information Infrastructure TX | Feb 3, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
2 | Grant |
| 15E 6 GHz Standard Power Access Point | Feb 3, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
2 | Grant |
Frequency bands (7)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 5180 – 5240 | 643 mW | 15E | — | — | CC MO |
| 5745 – 5825 | 830 mW | 15E | — | — | CC MO |
| 5955 – 6415 | 3.963 W | 15E | — | — | CC EP MO |
| 6535 – 6855 | 3.963 W | 15E | — | — | CC EP MO |
| 2402 – 2480 | 7 mW | 15C | — | — | CC |
| 2405 – 2480 | 23 mW | 15C | — | — | CC |
| 2412 – 2462 | 973 mW | 15C | — | — | CC MO |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Digital Transmission System. Output Power listed is the maximum combined conducted output power. Professional installation required. For pole or wall… (842 characters, open to read all)
Output Power listed is the maximum combined conducted output power. Professional installation required. For pole or wall mount installations, this device must be installed to provide a separation distance of at least 40 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. For under-seat or floor installations (model AP5060U only), RF exposure compliance for body exposure (under seat) configurations is limited installations establishing a minimum separation distance of 25 mm, as described in this filing. The highest reported SAR values for body, simultaneous transmission and product-specific (10g extremity SAR) use conditions are 0.37 W/kg, 1.46 W/kg and 0.53 W/kg, respectively. This device supports 20 MHz bandwidth modes.
Unlicensed National Information Infrastructure TX. Output Power listed is the maximum combined conducted output power. Professional installation required. For pole or wall… (853 characters, open to read all)
Output Power listed is the maximum combined conducted output power. Professional installation required. For pole or wall mount installations, this device must be installed to provide a separation distance of at least 40 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. For under-seat or floor installations (model AP5060U only), RF exposure compliance for body exposure (under seat) configurations is limited installations establishing a minimum separation distance of 25 mm, as described in this filing. The highest reported SAR values for body, simultaneous transmission and product-specific (10g extremity SAR) use conditions are 0.67 W/kg, 1.53 W/kg and 1.60 W/kg, respectively. This device supports 20, 40 and 80 MHz bandwidth modes.
15E 6 GHz Standard Power Access Point. Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. Profess… (1081 characters, open to read all)
Power listed is EIRP. Device operates with specific antennas in MIMO configurations as described in this filing. Professional installation required. For pole or wall mount installations, this device must be installed to provide a separation distance of at least 40 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. For under-seat or floor installations (model AP5060U only), RF exposure compliance for body exposure (under seat) configurations is limited installations establishing a minimum separation distance of 25 mm, as described in this filing. The highest reported SAR values for body, simultaneous transmission and product-specific (10g extremity SAR) use conditions are 0.15 W/kg, 1.53 W/kg and 0.35 W/kg, respectively. The highest reported power density is 6.70 W/m2 Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80, 160 and 320 MHz bandwidth modes.
History
- Oct 20, 2026: grant first recorded in FCC Radar.
Other devices by Extreme Networks, Inc.
All 10 FCC IDs of Extreme Networks, Inc..
Recent 6SD devices
15E 6 GHz Standard Power Access Point devices granted closest in time to QXO-AP5060.
All 59 FCC IDs in class 15E 6 GHz Standard Power Access Point.
Recent DTS devices
Digital Transmission System devices granted closest in time to QXO-AP5060.
All 18017 FCC IDs in class Digital Transmission System.
Recent NII devices
Unlicensed National Information Infrastructure TX devices granted closest in time to QXO-AP5060.
All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.