FCC Radar

FCC ID lookup › Getac Technology Corporation › QYLWCN6856Z12

FCC ID QYLWCN6856Z12

Tablet

Company
Getac Technology Corporation (grantee code QYL, Taiwan)
Product code
WCN6856Z12
Latest grant
Nov 17, 2026 — Class II Permissive Change
Equipment classes
15E 6 GHz Low Power Indoor Client (6XD); Digital Transmission System (DTS); Unlicensed National Information Infrastructure TX (NII)
Certified by
Kiwa Nederland B.V.
FCC record
Grant of equipment authorization at apps.fcc.gov

Class II Permissive Change — granted Nov 17, 2026

Applications (3)

Equipment classApplication datedTCBBandsFCC record
Unlicensed National Information Infrastructure TX Nov 11, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
4 Grant
Digital Transmission System Nov 11, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
2 Grant
15E 6 GHz Low Power Indoor Client Nov 11, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
4 Grant

Frequency bands (10)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
5180 – 5240 49 mW 15E — — CC MO
5260 – 5320 48 mW 15E — — CC MO ND
5500 – 5700 35 mW 15E — — CC MO ND
5745 – 5825 34 mW 15E — — CC MO
5955 – 6415 81 mW 15E — — CC EP MO
6435 – 6515 86 mW 15E — — CC EP MO
6535 – 6855 88 mW 15E — — CC EP MO
6875 – 7115 74 mW 15E — — CC EP MO
2402 – 2480 2.9 mW 15C — — CC
2412 – 2462 450 mW 15C — — CC MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Unlicensed National Information Infrastructure TX. Class II Permissive Change : Add partial RU functionality by software Output power listed is conducted. SAR compliance f… (998 characters, open to read all)

Class II Permissive Change : Add partial RU functionality by software Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.76 W/kg and 0.92 W/kg, respectively. Device is a device containing a 2 x 2 MIMO configuration, enabled for 5 band operations as described in this filing. This device has 20/40/80/160 MHz bandwidth modes. The 80 MHz modes are limited to channel at 5210MHz, 5290 MHz, 5530 MHz, 5690 MHz and 5775 MHz. The 160 MHz modes are limited to channel at 5250MHz and 5570 MHz.

Digital Transmission System. Class II Permissive Change : Add partial RU functionality by software Output power listed is conducted. SAR compliance f… (832 characters, open to read all)

Class II Permissive Change : Add partial RU functionality by software Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.75 W/kg and 0.92 W/kg, respectively. Device is a device containing a 2 x 2 MIMO configuration, enabled for 2.4 band operations as described in this filing. This device has 20/40 MHz bandwidth modes.

15E 6 GHz Low Power Indoor Client. Class II Permissive Change : Add partial RU functionality by software Power Output listed is Maximum EIRP. SAR complianc… (913 characters, open to read all)

Class II Permissive Change : Add partial RU functionality by software Power Output listed is Maximum EIRP. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.43 W/kg and 0.92 W/kg, respectively. Device is a device containing a 2 x 2 MIMO configuration, enabled for 6 band operations as described in this filing. Device operation is intended for indoor use only. This device supports 20 MHz, 40 MHz, 80 MHz and 160 MHz bandwidth modes.

History

Other devices by Getac Technology Corporation

All 19 FCC IDs of Getac Technology Corporation.

Recent 6XD devices

15E 6 GHz Low Power Indoor Client devices granted closest in time to QYLWCN6856Z12.

All 289 FCC IDs in class 15E 6 GHz Low Power Indoor Client.

Recent DTS devices

Digital Transmission System devices granted closest in time to QYLWCN6856Z12.

All 18017 FCC IDs in class Digital Transmission System.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to QYLWCN6856Z12.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.