FCC Radar

FCC ID lookup › EDAN INSTRUMENTS, INC. › SMQIT50

FCC ID SMQIT50

Telemetry Monitor

Company
EDAN INSTRUMENTS, INC. (grantee code SMQ, China)
Product code
IT50
Latest grant
Jan 30, 2026 — Original Equipment
Equipment classes
Digital Transmission System (DTS); Part 15 Low Power Communication Device Transmitter (DXX); Unlicensed National Information Infrastructure TX (NII)
Certified by
KL-Certification GmbH
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted Jan 30, 2026

Applications (3)

Equipment classApplication datedTCBBandsFCC record
Unlicensed National Information Infrastructure TX Jan 30, 2026 KL-Certification GmbH
St. Ingbert, Germany
2 Grant
Digital Transmission System Jan 30, 2026 KL-Certification GmbH
St. Ingbert, Germany
2 Grant
Part 15 Low Power Communication Device Transmitter Jan 30, 2026 KL-Certification GmbH
St. Ingbert, Germany
1 Grant

Frequency bands (5)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
13.56 — 15C — — CC
2402 – 2480 1.6 mW 15C — — CC
2412 – 2462 33.6 mW 15C — — CC
5180 – 5240 20.7 mW 15E — — CC
5745 – 5825 32.1 mW 15E — — CC

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Unlicensed National Information Infrastructure TX. Output power listed is average conducted. This device supports 802.11a and 802.11n with a 20 MHz and 40 MHz bandwidth mode. For body worn operation, this device has been tested and meets FCC RF exposure guidelines when used at a minimum distance of 0 mm from the body. The highest reported SAR for body-worn and simultaneous transmission use conditions are 0.52 W/kg and 0.60 W/kg respectively.
Digital Transmission System. Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. For body worn operation, this device has been tested and meets FCC RF exposure guidelines when used at a minimum distance of 0 mm from the body. The highest reported SAR for body-worn and simultaneous transmission use conditions are 0.52 W/kg and 0.60 W/kg respectively.

History

Other devices by EDAN INSTRUMENTS, INC.

All 8 FCC IDs of EDAN INSTRUMENTS, INC..

Recent DTS devices

Digital Transmission System devices granted closest in time to SMQIT50.

All 18017 FCC IDs in class Digital Transmission System.

Recent DXX devices

Part 15 Low Power Communication Device Transmitter devices granted closest in time to SMQIT50.

All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to SMQIT50.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.