FCC ID lookup › Roche Diagnostics GmbH › VO9-ACI2PAN9028
FCC ID VO9-ACI2PAN9028
IVD for monitoring blood glucose. (BGM)
- Company
- Roche Diagnostics GmbH (grantee code VO9, Germany)
- Product code
- ACI2PAN9028
- Latest grant
- Jul 24, 2026 — Original Equipment
- Equipment classes
- Digital Transmission System (DTS); Unlicensed National Information Infrastructure TX (NII)
- Certified by
- cetecom advanced GmbH
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Original Equipment — granted Jul 24, 2026
Applications (2)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| Unlicensed National Information Infrastructure TX | Jul 23, 2026 | cetecom advanced GmbH Saarbruecken, Germany |
1 | Grant |
| Digital Transmission System | Jul 23, 2026 | cetecom advanced GmbH Saarbruecken, Germany |
1 | Grant |
Frequency bands (2)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 2412 – 2462 | 181.97 mW | 15C | — | — | CC |
| 5180 – 5240 | 20.42 mW | 15E | — | — | CC |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Unlicensed National Information Infrastructure TX. Output power listed is average conducted. This device supports IEEE 802.11a (Wi-Fi 2) with a 20 MHz bandwidth mode, IEEE 802.11n (Wi-Fi 3) with a 20 MHz and 40 MHz bandwidth mode and IEEE 802.11ac (Wi-Fi 5) with a 20 MHz, 40 MHz and 80 MHz bandwidth mode. This device has been tested touched to the phantom and meets FCC RF exposure guidelines. The highest reported SAR for body-worn and extremities SAR exposure conditions are 1.127 W/kg and 0.389 W/kg, respectively.
Digital Transmission System. Output power listed is peak conducted. This device supports IEEE 802.11b (Wi-Fi 1) with a 20 MHz bandwidth mode, IEEE 802.11g (Wi-Fi 3) with a 20 MHz bandwidth mode and IEEE 802.11n (Wi-Fi 4) with a 20 MHz and 40 MHz bandwidth mode. This device has been tested touched to the phantom and meets FCC RF exposure guidelines. The highest reported SAR for body-worn and extremities SAR exposure conditions are 0.640 W/kg and 0.293 W/kg, respectively.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Recent DTS devices
Digital Transmission System devices granted closest in time to VO9-ACI2PAN9028.
All 18017 FCC IDs in class Digital Transmission System.
Recent NII devices
Unlicensed National Information Infrastructure TX devices granted closest in time to VO9-ACI2PAN9028.
All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.