FCC Radar

FCC ID lookup › TSC Auto ID Technology Co., Ltd. › VTVT30W1

FCC ID VTVT30W1

Smart Tablet Computer

Company
TSC Auto ID Technology Co., Ltd. (grantee code VTV, Taiwan)
Product code
T30W1
Latest grant
Oct 1, 2026 — Original Equipment
Equipment classes
15E 6 GHz Low Power Indoor Client (6XD); Digital Transmission System (DTS); Part 15 Class B Computing Device Peripheral (JBP); Part 15 Low Power Communication Device Transmitter (DXX); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
QAI LABORATORIES LTD
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted Oct 1, 2026

Grant 1 of 2 for this FCC ID.

Application (1)

Equipment classApplication datedTCBBandsFCC record
15E 6 GHz Low Power Indoor Client Oct 1, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
4 Grant

Frequency bands (4)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
5955 – 6415 5 mW 15E — — CC EP MO
6435 – 6515 4.9 mW 15E — — CC EP MO
6535 – 6855 5 mW 15E — — CC EP MO
6895 – 7115 5 mW 15E — — CC EP MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Output Power listed is EIRP. This device has 20, 40, 80 and 160 MHz bandwidth modes. Device is a 2x2 MIMO as is describe… (865 characters, open to read all)

Output Power listed is EIRP. This device has 20, 40, 80 and 160 MHz bandwidth modes. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.58W/kg, 0.58W/kg and 0.67W/kg respectively. The highest reported power density is 4.27 W/m2. Device 6 GHz operation is intended for indoor use only.

History

Original Equipment — granted Sep 4, 2026

Grant 2 of 2 for this FCC ID.

Applications (5)

Equipment classApplication datedTCBBandsFCC record
Part 15 Low Power Communication Device Transmitter Sep 3, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
1 Grant
Part 15 Class B Computing Device Peripheral Sep 3, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
1 Grant
Unlicensed National Information Infrastructure TX Sep 3, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
4 Grant
Digital Transmission System Sep 3, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
2 Grant
Part 15 Spread Spectrum Transmitter Sep 3, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
1 Grant

Frequency bands (9)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
2402 – 2480 7.8 mW 15C — — CC DR
2412 – 2462 21 mW 15C — — CC DR MO
13.56 — 15C — — CC
— — 15B — — CC
5180 – 5240 12.6 mW 15E — — CC DR MO
5260 – 5320 10.2 mW 15E — — CC DR MO ND
5500 – 5700 15.2 mW 15E — — CC DR MO ND
5745 – 5825 14.2 mW 15E — — CC DR MO
2402 – 2480 10.9 mW 15C — — CC DR

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Unlicensed National Information Infrastructure TX. Output power listed is maximum combined conducted power. This device contains 20, 40, 80 and 160 MHz signal bandwidth. D… (794 characters, open to read all)

Output power listed is maximum combined conducted power. This device contains 20, 40, 80 and 160 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.45W/kg, 0.45W/kg and 0.53W/kg respectively.

Digital Transmission System. Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is … (785 characters, open to read all)

Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.45W/kg, 0.45W/kg and 0.54W/kg respectively.

Part 15 Spread Spectrum Transmitter. Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific… (663 characters, open to read all)

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.09W/kg, 0.09W/kg and 0.67W/kg respectively.

History

Other devices by TSC Auto ID Technology Co., Ltd.

All 9 FCC IDs of TSC Auto ID Technology Co., Ltd..

Recent 6XD devices

15E 6 GHz Low Power Indoor Client devices granted closest in time to VTVT30W1.

All 289 FCC IDs in class 15E 6 GHz Low Power Indoor Client.

Recent DTS devices

Digital Transmission System devices granted closest in time to VTVT30W1.

All 18017 FCC IDs in class Digital Transmission System.

Recent JBP devices

Part 15 Class B Computing Device Peripheral devices granted closest in time to VTVT30W1.

All 609 FCC IDs in class Part 15 Class B Computing Device Peripheral.

Recent DXX devices

Part 15 Low Power Communication Device Transmitter devices granted closest in time to VTVT30W1.

All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to VTVT30W1.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to VTVT30W1.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.