FCC ID lookup › u-blox AG › XPYUBX19KM01
FCC ID XPYUBX19KM01
LTE CAT-M1 Module
- Company
- u-blox AG (grantee code XPY, Switzerland)
- Product code
- UBX19KM01
- Latest grant
- Aug 26, 2026 — Class II Permissive Change
- Equipment class
- PCS Licensed Transmitter (PCB)
- Certified by
- IIA Lab Services, LLC
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Class II Permissive Change — granted Aug 26, 2026
Grant 1 of 2 for this FCC ID.
Application (1)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| PCS Licensed Transmitter | Aug 21, 2026 | IIA Lab Services, LLC Alachua, FL, United States |
6 | Grant |
Frequency bands (3)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 699.7 – 715.3 | 199.5 mW | 27 | 0.1 PM | 1M13G7D | BC |
| 1710.7 – 1754.3 | 212.8 mW | 27 | 0.1 PM | 1M13G7D | BC |
| 1850.7 – 1909.3 | 196.3 mW | 24E | 0.1 PM | 1M12G7D | BC |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Output Power is conducted at the antenna terminal. Single modular approval. This device is certified for mobile and fixe… (1213 characters, open to read all)
Output Power is conducted at the antenna terminal. Single modular approval. This device is certified for mobile and fixed application. Co-location of this module with other transmitters would require the use of FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. OEM integrators must ensure that the end user has no manual instructions to remove or install this module. For mobile operating configurations the antenna gain, including cable loss, must not exceed the gains documented in this filing for satisfying RF exposure compliance, as defined in 2.1091. Under no conditions may an antenna gain be used that would exceed the ERP and/or EIRP power limits as specified in Parts 22/24/27/90. The Grantee is responsible for providing the documentation required for modular use and this module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. Class II Permissive Change: Adds a new PIFA antenna, and the disabling of CAT-M1 bands 5, 8, 13, 25, 26, 66 and 71, as well as NB-IoT mode by software.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Class II Permissive Change — granted Feb 10, 2026
Grant 2 of 2 for this FCC ID.
Application (1)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| PCS Licensed Transmitter | Feb 10, 2026 | DEKRA Testing and Certification, S.A.U. Campanillas - Malaga, Spain |
26 | Grant |
Frequency bands (13)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 699.1 – 715.9 | 224.4 mW | 27 | 0.1 PM | 186KG7D | BC |
| 699.7 – 715.3 | 199.5 mW | 27 | 0.1 PM | 1M13G7D | BC |
| 777.1 – 786.9 | 214.8 mW | 27 | 0.1 PM | 186KG7D | BC |
| 777.7 – 786.3 | 206.5 mW | 27 | 0.1 PM | 1M13G7D | BC |
| 814.7 – 823.3 | 188.3 mW | 90 | 0.1 PM | 1M13G7D | BC |
| 824.1 – 848.9 | 182.4 mW | 22H | 0.1 PM | 185KG7D | BC |
| 824.7 – 848.3 | 202.7 mW | 22H | 0.1 PM | 1M13G7D | BC |
| 897.6 – 900.4 | 189.2 mW | 27 | 0.1 PM | 188KG7D | BC |
| 898.2 – 899.8 | 178.2 mW | 27 | 0.1 PM | 1M12G7D | BC |
| 1710.1 – 1754.9 | 191 mW | 27 | 0.1 PM | 186KG7D | BC |
| 1710.7 – 1754.3 | 212.8 mW | 27 | 0.1 PM | 1M13G7D | BC |
| 1850.1 – 1909.9 | 177.4 mW | 24E | 0.1 PM | 186KG7D | BC |
| 1850.7 – 1909.3 | 196.3 mW | 24E | 0.1 PM | 1M12G7D | BC |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
Output Power is conducted at the antenna terminal. Single Modular Approval. This device is certified for mobile and fixe… (1402 characters, open to read all)
Output Power is conducted at the antenna terminal. Single Modular Approval. This device is certified for mobile and fixed application. Co-location of this module with other transmitters would require the use of FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. OEM integrators must insure that the end user has no manual instructions to remove or install this module. For mobile operating configurations the antenna gain, including cable loss, must not exceed the gains documented in this filing for satisfying RF exposure compliance, as defined in 2.1091. Under no conditions may an antenna gain be used that would exceed the ERP and/or EIRP power limits as specified in Parts 22/24/27/90. The Grantee is responsible for providing the documentation required for modular use and this module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. Class II Permissive Change Application to implement the following modifications: - Testing the module with a specific host (ALTAIR io6), co-located with other radio technologies. - Evaluation of RF exposure for portable use, reducing the separation distance from 20 cm to portable conditions. - Deactivation of LTE bands 25, 66, 71, and 85.
History