FCC Radar

FCC ID lookup › u-blox AG › XPYUBX19KM01

FCC ID XPYUBX19KM01

LTE CAT-M1 Module

Company
u-blox AG (grantee code XPY, Switzerland)
Product code
UBX19KM01
Latest grant
Aug 26, 2026 — Class II Permissive Change
Equipment class
PCS Licensed Transmitter (PCB)
Certified by
IIA Lab Services, LLC
FCC record
Grant of equipment authorization at apps.fcc.gov

Class II Permissive Change — granted Aug 26, 2026

Grant 1 of 2 for this FCC ID.

Application (1)

Equipment classApplication datedTCBBandsFCC record
PCS Licensed Transmitter Aug 21, 2026 IIA Lab Services, LLC
Alachua, FL, United States
6 Grant

Frequency bands (3)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
699.7 – 715.3 199.5 mW 27 0.1 PM 1M13G7D BC
1710.7 – 1754.3 212.8 mW 27 0.1 PM 1M13G7D BC
1850.7 – 1909.3 196.3 mW 24E 0.1 PM 1M12G7D BC

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Output Power is conducted at the antenna terminal. Single modular approval. This device is certified for mobile and fixe… (1213 characters, open to read all)

Output Power is conducted at the antenna terminal. Single modular approval. This device is certified for mobile and fixed application. Co-location of this module with other transmitters would require the use of FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. OEM integrators must ensure that the end user has no manual instructions to remove or install this module. For mobile operating configurations the antenna gain, including cable loss, must not exceed the gains documented in this filing for satisfying RF exposure compliance, as defined in 2.1091. Under no conditions may an antenna gain be used that would exceed the ERP and/or EIRP power limits as specified in Parts 22/24/27/90. The Grantee is responsible for providing the documentation required for modular use and this module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. Class II Permissive Change: Adds a new PIFA antenna, and the disabling of CAT-M1 bands 5, 8, 13, 25, 26, 66 and 71, as well as NB-IoT mode by software.

History

Class II Permissive Change — granted Feb 10, 2026

Grant 2 of 2 for this FCC ID.

Application (1)

Equipment classApplication datedTCBBandsFCC record
PCS Licensed Transmitter Feb 10, 2026 DEKRA Testing and Certification, S.A.U.
Campanillas - Malaga, Spain
26 Grant

Frequency bands (13)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
699.1 – 715.9 224.4 mW 27 0.1 PM 186KG7D BC
699.7 – 715.3 199.5 mW 27 0.1 PM 1M13G7D BC
777.1 – 786.9 214.8 mW 27 0.1 PM 186KG7D BC
777.7 – 786.3 206.5 mW 27 0.1 PM 1M13G7D BC
814.7 – 823.3 188.3 mW 90 0.1 PM 1M13G7D BC
824.1 – 848.9 182.4 mW 22H 0.1 PM 185KG7D BC
824.7 – 848.3 202.7 mW 22H 0.1 PM 1M13G7D BC
897.6 – 900.4 189.2 mW 27 0.1 PM 188KG7D BC
898.2 – 899.8 178.2 mW 27 0.1 PM 1M12G7D BC
1710.1 – 1754.9 191 mW 27 0.1 PM 186KG7D BC
1710.7 – 1754.3 212.8 mW 27 0.1 PM 1M13G7D BC
1850.1 – 1909.9 177.4 mW 24E 0.1 PM 186KG7D BC
1850.7 – 1909.3 196.3 mW 24E 0.1 PM 1M12G7D BC

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Output Power is conducted at the antenna terminal. Single Modular Approval. This device is certified for mobile and fixe… (1402 characters, open to read all)

Output Power is conducted at the antenna terminal. Single Modular Approval. This device is certified for mobile and fixed application. Co-location of this module with other transmitters would require the use of FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. OEM integrators must insure that the end user has no manual instructions to remove or install this module. For mobile operating configurations the antenna gain, including cable loss, must not exceed the gains documented in this filing for satisfying RF exposure compliance, as defined in 2.1091. Under no conditions may an antenna gain be used that would exceed the ERP and/or EIRP power limits as specified in Parts 22/24/27/90. The Grantee is responsible for providing the documentation required for modular use and this module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. Class II Permissive Change Application to implement the following modifications: - Testing the module with a specific host (ALTAIR io6), co-located with other radio technologies. - Evaluation of RF exposure for portable use, reducing the separation distance from 20 cm to portable conditions. - Deactivation of LTE bands 25, 66, 71, and 85.

History

Other devices by u-blox AG

All 11 FCC IDs of u-blox AG.

Recent PCB devices

PCS Licensed Transmitter devices granted closest in time to XPYUBX19KM01.

All 1088 FCC IDs in class PCS Licensed Transmitter.