FCC ID lookup › UCLOUDLINK (SINGAPORE) PTE.LTD › 2BB6E-GLMU24A03
FCC ID 2BB6E-GLMU24A03
5G Wireless Data Terminal
- Company
- UCLOUDLINK (SINGAPORE) PTE.LTD (grantee code 2BB6E, Singapore)
- Product code
- GLMU24A03
- Latest grant
- May 21, 2026 — Original Equipment
- Equipment classes
- Citizens Band End User Devices (CBE); Digital Transmission System (DTS); Licensed Non-Broadcast Transmitter Worn on Body (TNT); PCS Licensed Transmitter worn on body (PCT); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
- Certified by
- Compliance Testing, LLC
- FCC record
- Grant of equipment authorization at apps.fcc.gov
Original Equipment — granted May 21, 2026
Applications (6)
| Equipment class | Application dated | TCB | Bands | FCC record |
|---|---|---|---|---|
| PCS Licensed Transmitter worn on body | May 20, 2026 | Compliance Testing, LLC Mesa, AZ, United States |
110 | Grant |
| Unlicensed National Information Infrastructure TX | May 21, 2026 | Compliance Testing, LLC Mesa, AZ, United States |
2 | Grant |
| Citizens Band End User Devices | May 21, 2026 | Compliance Testing, LLC Mesa, AZ, United States |
8 | Grant |
| Part 15 Spread Spectrum Transmitter | May 21, 2026 | Compliance Testing, LLC Mesa, AZ, United States |
1 | Grant |
| Digital Transmission System | May 21, 2026 | Compliance Testing, LLC Mesa, AZ, United States |
2 | Grant |
| Licensed Non-Broadcast Transmitter Worn on Body | May 21, 2026 | Compliance Testing, LLC Mesa, AZ, United States |
2 | Grant |
Frequency bands (58)
| Frequency range, MHz | Output power | Rule parts | Tolerance | Emission designator | Grant notes |
|---|---|---|---|---|---|
| 665.5 – 695.5 | 82 mW | 27 | 2.5 PM | 4M52W7D | — |
| 670.5 – 690.5 | 98 mW | 27 | 2.5 PM | 13M5G7D | — |
| 673 – 688 | 94 mW | 27 | 2.5 PM | 18M0G7D | — |
| 699.7 – 715.3 | 92 mW | 27 | 2.5 PM | 1M11W7D | — |
| 701.5 – 711 | 154 mW | 27 | 2.5 PM | 13M9G7D | — |
| 704 – 711 | 108 mW | 27 | 2.5 PM | 8M98G7D | — |
| 706.5 – 708.5 | 125 mW | 27 | 2.5 PM | 14M2G7D | — |
| 709 – 711 | 146 mW | 27 | 2.5 PM | 8M99G7D | — |
| 793 | 81 mW | 90 | 2.5 PM | 9M00G7D | — |
| 826.4 – 846.6 | 152 mW | 22H | 2.5 PM | 4M15F9W | — |
| 826.5 – 846.5 | 109 mW | 22H | 2.5 PM | 4M51G7D | — |
| 829 – 844 | 107 mW | 22H | 2.5 PM | 9M04G7D | — |
| 834 – 839 | 116 mW | 22H | 2.5 PM | 19M0G7D | — |
| 1710.7 – 1754.3 | 259 mW | 27 | 2.5 PM | 1M11G7D | — |
| 1711.5 – 1753.5 | 221 mW | 27 | 2.5 PM | 2M72W7D | — |
| 1711.5 – 1778.5 | 207 mW | 27 | 2.5 PM | 2M72W7D | — |
| 1712.4 – 1752.6 | 370 mW | 27 | 2.5 PM | 4M19F9W | — |
| 1712.5 – 1777.5 | 242 mW | 27 | 2.5 PM | 4M52G7D | — |
| 1717.5 – 1772.5 | 292 mW | 27 | 2.5 PM | 14M2W7D | — |
| 1720 – 1745 | 246 mW | 27 | 2.5 PM | 18M0G7D | — |
| 1720 – 1770 | 231 mW | 27 | 2.5 PM | 18M0G7D | — |
| 1851.5 – 1908.5 | 434 mW | 24E | 2.5 PM | 2M71G7D | — |
| 1851.5 – 1913.5 | 418 mW | 24E | 2.5 PM | 2M71G7D | — |
| 1852.4 – 1907.6 | 625 mW | 24E | 2.5 PM | 4M17F9W | — |
| 1855 – 1910 | 348 mW | 24E | 2.5 PM | 9M02W7D | — |
| 1857.5 – 1902.5 | 468 mW | 24E | 2.5 PM | 14M2G7D | — |
| 1857.5 – 1907.5 | 436 mW | 24E | 2.5 PM | 14M2G7D | — |
| 1860 – 1900 | 404 mW | 24E | 2.5 PM | 18M0G7D | — |
| 1860 – 1905 | 397 mW | 24E | 2.5 PM | 18M0G7D | — |
| 2498.5 – 2687.5 | 199 mW | 27 | 2.5 PM | 4M52G7D | — |
| 2506 – 2680 | 194 mW | 27 | 2.5 PM | 18M0G7D | — |
| 2507.5 – 2562.5 | 195 mW | 27 | 2.5 PM | 13M5G7D | — |
| 2510 – 2560 | 192 mW | 27 | 2.5 PM | 18M0G7D | — |
| 2521.02 – 2664.99 | 207 mW | 27 | 2.5 PM | 47M6G7D | — |
| 2546.01 – 2640 | 204 mW | 27 | 2.5 PM | 97M6G7D | — |
| 2572.5 – 2617.5 | 164 mW | 27 | 2.5 PM | 4M55W7D | — |
| 2575 – 2615 | 196 mW | 27 | 2.5 PM | 9M05G7D | — |
| 2580 – 2610 | 186 mW | 27 | 2.5 PM | 18M1G7D | — |
| 2590 – 2600 | 201 mW | 27 | 2.5 PM | 38M0G7D | — |
| 3452.5 – 3547.5 | 184 mW | 27 | 2.5 PM | 4M52G7D | — |
| 3460 – 3540 | 174 mW | 27 | 2.5 PM | 18M0G7D | — |
| 3465 – 3534.99 | 224 mW | 27 | 2.5 PM | 28M0G7D | — |
| 3500.01 | 192 mW | 27 | 2.5 PM | 97M9G7D | — |
| 3710.01 – 3969.99 | 237 mW | 27 | 2.5 PM | 18M3G7D | — |
| 3720 – 3780 | 225 mW | 27 | 2.5 PM | 38M0G7D | — |
| 3750 | 208 mW | 27 | 2.5 PM | 97M4G7D | — |
| 3750 – 3930 | 224 mW | 27 | 2.5 PM | 97M7G7D | — |
| 5180 – 5240 | 112.7 mW | 15E | — | — | CC MO |
| 5745 – 5825 | 102.6 mW | 15E | — | — | CC MO |
| 1626.6 – 1660.4 | 249.5 mW | 25 | 0.0019 PM | 184KG7D | — |
| 2000.1 – 2019.9 | 221.8 mW | 25 | 0.2218 PM | 185KG7D | — |
| 2402 – 2480 | 18.7 mW | 15C | — | — | CC |
| 3506.01 – 3690 | 177 mW | 96 | 2.5 PM | 18M4G7D | — |
| 3555 – 3695 | 163 mW | 96 | 2.5 PM | 9M03G7D | — |
| 3560 – 3690 | 155 mW | 96 | 2.5 PM | 18M0G7D | — |
| 3570 – 3679.98 | 176 mW | 96 | 2.5 PM | 38M0G7D | — |
| 2402 – 2480 | 7.4 mW | 15C | — | — | CC |
| 2412 – 2462 | 145.9 mW | 15C | — | — | CC MO |
Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.
Grant conditions
PCS Licensed Transmitter worn on body. Output power listed is ERP for operation below 1 GHz and EIRP for operation above 1 GHz. LTE supports 1.4/3/5/10/15/20 M… (1622 characters, open to read all)
Output power listed is ERP for operation below 1 GHz and EIRP for operation above 1 GHz. LTE supports 1.4/3/5/10/15/20 MHz BW modes in Band 2/4/25/66, 1.4/3/5/10 MHz BW modes in Band 5/12, 5/10/15/20 MHz BW modes in Band 7/38/41/42/71, and 5/10 MHz BW modes in Band 14/17. 5G NR supports 5/10/15/20 MHz BW modes in n2/5/7/25/66/71, 5/10/15 MHz BW modes in n12, 20/30/40 MHz BW modes in n38, 20/30/40/50/60/80/100 MHz BW modes in n41, and 20/30/40/60/80/100 MHz BW modes in n77/78. The device supports LTE UL CA bands CA_2C, CA_5B, CA_7C, CA_12B, CA_38C, CA_41C, CA_42C, CA_66C. The primarily intended use of the device is outdoor travelling. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.24 W/kg and 2.55 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.59 W/kg and 3.51 W/kg respectively. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.
Unlicensed National Information Infrastructure TX. RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The primarily i… (1023 characters, open to read all)
RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The primarily intended use of the device is outdoor travelling. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.57 W/kg and 0.68 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.59 W/kg and 3.29 W/kg respectively.
Citizens Band End User Devices. Output power listed is EIRP for LTE Band 48 and 5G NR n48. It supports 5/10/15/20 MHz BW modes in Band 48 and 20/40 MHz … (1061 characters, open to read all)
Output power listed is EIRP for LTE Band 48 and 5G NR n48. It supports 5/10/15/20 MHz BW modes in Band 48 and 20/40 MHz BW modes in 5G NR n48. The primarily intended use of the device is outdoor travelling. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.43 W/kg and 0.95 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.59 W/kg and 3.51 W/kg respectively.
Part 15 Spread Spectrum Transmitter. RF output power is conducted. The primarily intended use of the device is outdoor travelling. The antenna(s) used for th… (948 characters, open to read all)
RF output power is conducted. The primarily intended use of the device is outdoor travelling. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.02 W/kg and 0.04 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.59 W/kg and 3.29 W/kg respectively.
Digital Transmission System. RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20 and 40 MHz BW modes. The primarily inten… (1019 characters, open to read all)
RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20 and 40 MHz BW modes. The primarily intended use of the device is outdoor travelling. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.40 W/kg and 0.65 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.58 W/kg and 3.51 W/kg respectively.
Licensed Non-Broadcast Transmitter Worn on Body. Output power listed is EIRP. This device supports 3.75 and 15 kHz bandwidth modes for FDD Bands 23 and 255. The primaril… (1026 characters, open to read all)
Output power listed is EIRP. This device supports 3.75 and 15 kHz bandwidth modes for FDD Bands 23 and 255. The primarily intended use of the device is outdoor travelling. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.39 W/kg and 1.26 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.59 W/kg and 3.51 W/kg respectively.
History
- Oct 19, 2026: grant first recorded in FCC Radar.
Other devices by UCLOUDLINK (SINGAPORE) PTE.LTD
Recent CBE devices
Citizens Band End User Devices devices granted closest in time to 2BB6E-GLMU24A03.
All 287 FCC IDs in class Citizens Band End User Devices.
Recent DTS devices
Digital Transmission System devices granted closest in time to 2BB6E-GLMU24A03.
All 18017 FCC IDs in class Digital Transmission System.
Recent TNT devices
Licensed Non-Broadcast Transmitter Worn on Body devices granted closest in time to 2BB6E-GLMU24A03.
All 30 FCC IDs in class Licensed Non-Broadcast Transmitter Worn on Body.
Recent PCT devices
PCS Licensed Transmitter worn on body devices granted closest in time to 2BB6E-GLMU24A03.
All 113 FCC IDs in class PCS Licensed Transmitter worn on body.
Recent DSS devices
Part 15 Spread Spectrum Transmitter devices granted closest in time to 2BB6E-GLMU24A03.
All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.
Recent NII devices
Unlicensed National Information Infrastructure TX devices granted closest in time to 2BB6E-GLMU24A03.
All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.