FCC Radar

FCC ID lookup › Shanghai Sunmi Technology Co.,Ltd. › 2AH25T5F2ALN

FCC ID 2AH25T5F2ALN

Wireless data POS System

Company
Shanghai Sunmi Technology Co.,Ltd. (grantee code 2AH25, China)
Product code
T5F2ALN
Latest grant
May 21, 2026 — Original Equipment
Equipment classes
15E 6 GHz Low Power Indoor Client (6XD); Digital Transmission System (DTS); PCS Licensed Transmitter worn on body (PCT); Part 15 Class B Computing Device Peripheral (JBP); Part 15 Low Power Communication Device Transmitter (DXX); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
Kiwa Nederland B.V.
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted May 21, 2026

Applications (7)

Equipment classApplication datedTCBBandsFCC record
Digital Transmission System Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
2 Grant
Part 15 Spread Spectrum Transmitter Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant
Part 15 Class B Computing Device Peripheral Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant
Unlicensed National Information Infrastructure TX Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
4 Grant
Part 15 Low Power Communication Device Transmitter Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant
PCS Licensed Transmitter worn on body Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
33 Grant
15E 6 GHz Low Power Indoor Client Apr 28, 2026 Kiwa Nederland B.V.
Apeldoorn, NL-7300 AC, Netherlands
1 Grant

Frequency bands (22)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
— — 15B — — —
5180 – 5240 72 mW 15E — — CC MO
5260 – 5320 68 mW 15E — — CC MO ND
5500 – 5700 75 mW 15E — — CC MO ND
5745 – 5825 71 mW 15E — — CC MO
5925 – 7125 12 mW 15E — — CC EP MO
2402 – 2480 13 mW 15C — — CC
814.7 – 823.3 224 mW 90 2.5 PM 8M98G7D —
824.2 – 848.8 2.443 W 22H 2.5 PM 245KGXW —
824.7 – 848.3 206 mW 22H 2.5 PM 8M97G7D —
826.4 – 846.6 222 mW 22H 2.5 PM 4M10F9W —
1710.7 – 1754.3 240 mW 27 2.5 PM 17M9G7D —
1712.4 – 1752.6 262 mW 27 2.5 PM 4M11F9W —
1850.2 – 1909.8 1.18 W 24E 2.5 PM 244KGXW —
1850.7 – 1909.3 233 mW 24E 2.5 PM 17M9G7D —
1852.4 – 1907.6 252 mW 24E 2.5 PM 4M11F9W —
2498.5 – 2687.5 455 mW 27 2.5 PM 17M9G7D —
2502.5 – 2567.5 451 mW 27 2.5 PM 17M9G7D —
2572.5 – 2617.5 452 mW 27 2.5 PM 17M9G7D —
13.56 — 15C — — CC
2402 – 2480 7.9 mW 15C — — CC
2412 – 2462 89 mW 15C — — CC MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Digital Transmission System. RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20 BW mode only. The antenna(s) used for th… (950 characters, open to read all)

RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20 BW mode only. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.09 W/kg and 0.27 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.988 W/kg and 1.611 W/kg respectively.

Part 15 Spread Spectrum Transmitter. RF output power is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitter… (885 characters, open to read all)

RF output power is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.04 W/kg and 0.14 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.939 W/kg and 1.48 W/kg respectively.

Unlicensed National Information Infrastructure TX. RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The antenna(s) … (959 characters, open to read all)

RF output power is conducted. Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.23 W/kg and 1.45 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.58 W/kg and 1.80 W/kg respectively.

PCS Licensed Transmitter worn on body. Output power listed is ERP for operation below 1 GHz, EIRP for operation above 1 GHz, and conducted power for Part 90S (… (1285 characters, open to read all)

Output power listed is ERP for operation below 1 GHz, EIRP for operation above 1 GHz, and conducted power for Part 90S (814-824 MHz). LTE supports 1.4/3/5/10/15/20 MHz BW modes in Band 2/4, 1.4/3/5/10 MHz BW modes in Band 5, 5/10/15/20 MHz BW modes in Band 7/38/41, 1.4/3/5/10/15 MHz BW modes in Band 26. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.00 W/kg and 1.46 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.58 W/kg and 1.80 W/kg respectively. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations.

15E 6 GHz Low Power Indoor Client. RF output power is Effective Isotropic Radiated Power (EIRP). Device is a 2 x 2 MIMO configuration, supports 20, 40 and … (1059 characters, open to read all)

RF output power is Effective Isotropic Radiated Power (EIRP). Device is a 2 x 2 MIMO configuration, supports 20, 40 and 80 MHz BW modes. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 10 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported standalone 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 0.22 W/kg and 021 W/kg respectively. The highest reported simultaneous 1g SAR for body (separation 10 mm) and 10g SAR for limbs (separation 0 mm) exposure conditions are 1.119 W/kg and 1.674 W/kg respectively. The highest reported power density (separation 2 mm) is 8.29 W/m2.

History

Other devices by Shanghai Sunmi Technology Co.,Ltd.

All 37 FCC IDs of Shanghai Sunmi Technology Co.,Ltd..

Recent 6XD devices

15E 6 GHz Low Power Indoor Client devices granted closest in time to 2AH25T5F2ALN.

All 289 FCC IDs in class 15E 6 GHz Low Power Indoor Client.

Recent DTS devices

Digital Transmission System devices granted closest in time to 2AH25T5F2ALN.

All 18017 FCC IDs in class Digital Transmission System.

Recent PCT devices

PCS Licensed Transmitter worn on body devices granted closest in time to 2AH25T5F2ALN.

All 113 FCC IDs in class PCS Licensed Transmitter worn on body.

Recent JBP devices

Part 15 Class B Computing Device Peripheral devices granted closest in time to 2AH25T5F2ALN.

All 609 FCC IDs in class Part 15 Class B Computing Device Peripheral.

Recent DXX devices

Part 15 Low Power Communication Device Transmitter devices granted closest in time to 2AH25T5F2ALN.

All 4782 FCC IDs in class Part 15 Low Power Communication Device Transmitter.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to 2AH25T5F2ALN.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to 2AH25T5F2ALN.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.