FCC Radar

FCC ID lookup › NOVISOLUTIONS CIA LTDA › 2BO9717PRO

FCC ID 2BO9717PRO

Smartphone

Company
NOVISOLUTIONS CIA LTDA (grantee code 2BO97, Ecuador)
Product code
17PRO
Latest grant
Sep 9, 2026 — Original Equipment
Equipment classes
Digital Transmission System (DTS); PCS Licensed Transmitter held to ear (PCE); Part 15 Class B Computing Device Peripheral (JBP); Part 15 Spread Spectrum Transmitter (DSS)
Certified by
QAI LABORATORIES LTD
FCC record
Grant of equipment authorization at apps.fcc.gov

Original Equipment — granted Sep 9, 2026

Applications (4)

Equipment classApplication datedTCBBandsFCC record
PCS Licensed Transmitter held to ear Sep 9, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
13 Grant
Digital Transmission System Sep 9, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
2 Grant
Part 15 Spread Spectrum Transmitter Sep 9, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
1 Grant
Part 15 Class B Computing Device Peripheral Sep 9, 2026 QAI LABORATORIES LTD
Burnaby, BC, Canada
1 Grant

Frequency bands (12)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
2402 – 2480 600 µW 15C — — CC
2412 – 2462 41.9 mW 15C — — CC
824.2 – 848.8 144.5 mW 22H 2.5 PM 249KGXW —
826.4 – 846.6 101.9 mW 22H 2.5 PM 4M17F9W —
1715 – 1750 64.1 mW 27 2.5 PM 9M01G7D —
1720 – 1745 63.2 mW 27 2.5 PM 18M0G7D —
1850.2 – 1909.8 200.9 mW 24E 2.5 PM 249KGXW —
1852.4 – 1907.6 214.3 mW 24E 2.5 PM 4M18F9W —
1852.5 – 1907.5 174.6 mW 24E 2.5 PM 4M51G7D —
1860 – 1900 174.6 mW 24E 2.5 PM 18M0G7D —
— — 15B — — CC
2402 – 2480 3.9 mW 15C — — CC

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

PCS Licensed Transmitter held to ear. Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn … (737 characters, open to read all)

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions are 0.56 W/kg, 1.05 W/kg, 1.05 W/kg and 1.21 W/kg respectively.

Digital Transmission System. Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-wor… (739 characters, open to read all)

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions are 0.49 W/kg, 0.16 W/kg, 0.16 W/kg and 1.21 W/kg respectively.

Part 15 Spread Spectrum Transmitter. Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific… (686 characters, open to read all)

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions are 0.17 W/kg, 0.17 W/kg, 0.17 W/kg and 1.21 W/kg respectively.

History

Other devices by NOVISOLUTIONS CIA LTDA

All 9 FCC IDs of NOVISOLUTIONS CIA LTDA.

Recent DTS devices

Digital Transmission System devices granted closest in time to 2BO9717PRO.

All 18017 FCC IDs in class Digital Transmission System.

Recent PCE devices

PCS Licensed Transmitter held to ear devices granted closest in time to 2BO9717PRO.

All 493 FCC IDs in class PCS Licensed Transmitter held to ear.

Recent JBP devices

Part 15 Class B Computing Device Peripheral devices granted closest in time to 2BO9717PRO.

All 609 FCC IDs in class Part 15 Class B Computing Device Peripheral.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to 2BO9717PRO.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.