FCC Radar

FCC ID lookup › Acer Incorporated › HLZMT7922A12L

FCC ID HLZMT7922A12L

2TX 11ax (WiFi6E) BW160+BT/BLE Cambo Card

Company
Acer Incorporated (grantee code HLZ, Taiwan)
Product code
MT7922A12L
Latest grant
Feb 13, 2026 — Class II Permissive Change
Equipment classes
15E 6 GHz Low Power Dual Client (6CD); Digital Transmission System (DTS); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
IIA Lab Services, LLC
FCC record
Grant of equipment authorization at apps.fcc.gov

Class II Permissive Change — granted Feb 13, 2026

Grant 1 of 2 for this FCC ID.

Applications (4)

Equipment classApplication datedTCBBandsFCC record
Part 15 Spread Spectrum Transmitter Feb 3, 2026 IIA Lab Services, LLC
Alachua, FL, United States
1 Grant
Unlicensed National Information Infrastructure TX Feb 3, 2026 IIA Lab Services, LLC
Alachua, FL, United States
9 Grant
15E 6 GHz Low Power Dual Client Feb 3, 2026 IIA Lab Services, LLC
Alachua, FL, United States
3 Grant
Digital Transmission System Feb 3, 2026 IIA Lab Services, LLC
Alachua, FL, United States
2 Grant

Frequency bands (15)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
2402 – 2480 22 mW 15C — — CC
2402 – 2480 20 mW 15C — — CC
2412 – 2472 770 mW 15C — — CC MO
5955 – 6415 993 mW 15E — — CC EP MO
5955 – 7115 56 mW 15E — — CC EP MO
6535 – 6855 974 mW 15E — — CC EP MO
5180 – 5250 193 mW 15E — — CC MO
5250 – 5320 198 mW 15E — — CC MO ND
5500 – 5720 244 mW 15E — — CC MO ND
5745 – 5825 256 mW 15E — — CC MO
5815 255 mW 15E — — CC EP MO
5835 304 mW 15E — — CC EP MO
5845 183 mW 15E — — CC EP MO
5855 491 mW 15E — — CC EP MO
5865 – 5885 303 mW 15E — — CC EP MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Part 15 Spread Spectrum Transmitter. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (971 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.36 W/kg and 1.58 W/kg, respectively. Class II Permissive Change: Authorizes portable use when integrated into the Acer Notebook Computer, model N26Q4. The highest reported SAR for body and simultaneous transmission exposure conditions are < 0.10 W/kg and 1.25 W/kg, respectively.

Unlicensed National Information Infrastructure TX. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (1162 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.79 W/kg and 1.58 W/kg, respectively. Device is a 2 x 2 MIMO configuration; operation is intended for indoor use only. This device has 20/40/80/160 MHz bandwidths. Class II Permissive Change: Authorizes portable use when integrated into the Acer Notebook Computer, model N26Q4. The highest reported SAR for body and simultaneous transmission exposure conditions are 1.20 W/kg and 1.25 W/kg, respectively.

15E 6 GHz Low Power Dual Client. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators.… (1114 characters, open to read all)

This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80/160 MHz bandwidths. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.76 W/kg and 1.55 W/kg, respectively. Class II Permissive Change: Authorizes portable use when integrated into the Acer Notebook Computer, model N26Q4. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.52 W/kg and 1.05 W/kg, respectively. The highest reported power density is 9.91 W/m2.

Digital Transmission System. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (1088 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.44 W/kg and 1.58 W/kg, respectively. Device is a 2 x 2 MIMO configuration; operation is intended for indoor use only. This device has 20/40 MHz bandwidths. Class II Permissive Change: Authorizes portable use when integrated into the Acer Notebook Computer, model N26Q4. The highest reported SAR for body and simultaneous transmission exposure conditions are 1.20 W/kg and 1.25 W/kg, respectively.

History

Change in Identification — granted Jan 13, 2026

Grant 2 of 2 for this FCC ID.

Applications (4)

Equipment classApplication datedTCBBandsFCC record
15E 6 GHz Low Power Dual Client Dec 26, 2025 IIA Lab Services, LLC
Alachua, FL, United States
3 Grant
Digital Transmission System Dec 26, 2025 IIA Lab Services, LLC
Alachua, FL, United States
2 Grant
Unlicensed National Information Infrastructure TX Dec 26, 2025 IIA Lab Services, LLC
Alachua, FL, United States
9 Grant
Part 15 Spread Spectrum Transmitter Dec 26, 2025 IIA Lab Services, LLC
Alachua, FL, United States
1 Grant

Frequency bands (15)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
5955 – 6415 993 mW 15E — — CC EP MO
5955 – 7115 56 mW 15E — — CC EP MO
6535 – 6855 974 mW 15E — — CC EP MO
5180 – 5250 193 mW 15E — — CC MO
5250 – 5320 198 mW 15E — — CC MO ND
5500 – 5720 244 mW 15E — — CC MO ND
5745 – 5825 256 mW 15E — — CC MO
5815 255 mW 15E — — CC EP MO
5835 304 mW 15E — — CC EP MO
5845 183 mW 15E — — CC EP MO
5855 491 mW 15E — — CC EP MO
5865 – 5885 303 mW 15E — — CC EP MO
2402 – 2480 22 mW 15C — — CC
2402 – 2480 20 mW 15C — — CC
2412 – 2472 770 mW 15C — — CC MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

15E 6 GHz Low Power Dual Client. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators.… (824 characters, open to read all)

This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80/160 MHz bandwidths. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.76 W/kg and 1.55 W/kg, respectively.

Digital Transmission System. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (847 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.44 W/kg and 1.58 W/kg, respectively. Device is a 2 x 2 MIMO configuration; operation is intended for indoor use only. This device has 20/40 MHz bandwidths.

Unlicensed National Information Infrastructure TX. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (921 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.79 W/kg and 1.58 W/kg, respectively. Device is a 2 x 2 MIMO configuration; operation is intended for indoor use only. This device has 20/40/80/160 MHz bandwidths.

Part 15 Spread Spectrum Transmitter. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (728 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.36 W/kg and 1.58 W/kg, respectively.

History

Other devices by Acer Incorporated

All 35 FCC IDs of Acer Incorporated.

Recent 6CD devices

15E 6 GHz Low Power Dual Client devices granted closest in time to HLZMT7922A12L.

All 215 FCC IDs in class 15E 6 GHz Low Power Dual Client.

Recent DTS devices

Digital Transmission System devices granted closest in time to HLZMT7922A12L.

All 18017 FCC IDs in class Digital Transmission System.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to HLZMT7922A12L.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to HLZMT7922A12L.