FCC Radar

FCC ID lookup › Acer Incorporated › HLZMT7925B14L

FCC ID HLZMT7925B14L

2TX 11be (WiFi7) BW160+BT/BLE Combo Card

Company
Acer Incorporated (grantee code HLZ, Taiwan)
Product code
MT7925B14L
Latest grant
Feb 11, 2026 — Class II Permissive Change
Equipment classes
15E 6 GHZ Very Low Power Device (6VL); 15E 6 GHz Low Power Dual Client (6CD); Digital Transmission System (DTS); Part 15 Spread Spectrum Transmitter (DSS); Unlicensed National Information Infrastructure TX (NII)
Certified by
IIA Lab Services, LLC
FCC record
Grant of equipment authorization at apps.fcc.gov

Class II Permissive Change — granted Feb 11, 2026

Grant 1 of 2 for this FCC ID.

Applications (5)

Equipment classApplication datedTCBBandsFCC record
15E 6 GHZ Very Low Power Device Feb 4, 2026 IIA Lab Services, LLC
Alachua, FL, United States
1 Grant
Digital Transmission System Feb 4, 2026 IIA Lab Services, LLC
Alachua, FL, United States
2 Grant
Part 15 Spread Spectrum Transmitter Feb 4, 2026 IIA Lab Services, LLC
Alachua, FL, United States
1 Grant
Unlicensed National Information Infrastructure TX Feb 4, 2026 IIA Lab Services, LLC
Alachua, FL, United States
9 Grant
15E 6 GHz Low Power Dual Client Feb 4, 2026 IIA Lab Services, LLC
Alachua, FL, United States
3 Grant

Frequency bands (16)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
2402 – 2480 19 mW 15C — — CC
2412 – 2472 303 mW 15C — — CC MO
5180 – 5250 245 mW 15E — — CC MO
5250 – 5320 249 mW 15E — — CC MO ND
5500 – 5720 244 mW 15E — — CC MO ND
5745 – 5825 554 mW 15E — — CC MO
5815 475 mW 15E — — CC EP MO
5835 891 mW 15E — — CC EP MO
5845 458 mW 15E — — CC EP MO
5855 870 mW 15E — — CC EP MO
5865 – 5885 941 mW 15E — — CC EP MO
5955 – 7115 25 mW 15E — — MO
2402 – 2480 19 mW 15C — — CC
5955 – 6415 965 mW 15E — — CC EP MO
5955 – 7115 109 mW 15E — — CC EP MO
6535 – 6885 988 mW 15E — — CC EP MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

15E 6 GHZ Very Low Power Device. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators.… (1103 characters, open to read all)

This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Besides, the SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR value for body use conditions is 0.28 W/kg. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. Class II Permissive Change: Authorizes portable use when integrated into the Acer Notebook Computer, model N26Q4. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.93 W/kg and 1.58 W/kg, respectively. The highest reported power density is 9.53 W/m2.

Digital Transmission System. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (882 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antennas used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.55 W/kg and 1.59 W/kg, respectively. Class II Permissive Change: Authorizes portable use when integrated into the Acer Notebook Computer, model N26Q4. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.79 W/kg and 1.53 W/kg, respectively.

Part 15 Spread Spectrum Transmitter. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (884 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antennas used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.14 W/kg and 1.59 W/kg, respectively. Class II Permissive Change: Authorizes portable use when integrated into the Acer Notebook Computer, model N26Q4. The highest reported SAR for body and simultaneous transmission exposure conditions are < 0.10 W/kg and 1.10 W/kg, respectively.

Unlicensed National Information Infrastructure TX. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (882 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antennas used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.80 W/kg and 1.59 W/kg, respectively. Class II Permissive Change: Authorizes portable use when integrated into the Acer Notebook Computer, model N26Q4. The highest reported SAR for body and simultaneous transmission exposure conditions are 1.05 W/kg and 1.10 W/kg, respectively.

15E 6 GHz Low Power Dual Client. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators.… (915 characters, open to read all)

This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antennas used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR and Power Density has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.77 W/kg and 1.59 W/kg, respectively. Class II Permissive Change: Authorizes portable use when integrated into the Acer Notebook Computer, model N26Q4. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.93 W/kg and 1.58 W/kg, respectively. The highest reported power density is 9.53 W/m2.

History

Change in Identification — granted Jan 8, 2026

Grant 2 of 2 for this FCC ID.

Applications (5)

Equipment classApplication datedTCBBandsFCC record
Part 15 Spread Spectrum Transmitter Dec 30, 2025 IIA Lab Services, LLC
Alachua, FL, United States
1 Grant
Digital Transmission System Dec 30, 2025 IIA Lab Services, LLC
Alachua, FL, United States
2 Grant
15E 6 GHz Low Power Dual Client Dec 30, 2025 IIA Lab Services, LLC
Alachua, FL, United States
3 Grant
15E 6 GHZ Very Low Power Device Dec 30, 2025 IIA Lab Services, LLC
Alachua, FL, United States
1 Grant
Unlicensed National Information Infrastructure TX Dec 30, 2025 IIA Lab Services, LLC
Alachua, FL, United States
9 Grant

Frequency bands (16)

Frequency range, MHzOutput powerRule partsToleranceEmission designatorGrant notes
2402 – 2480 19 mW 15C — — CC
2412 – 2472 303 mW 15C — — CC MO
2402 – 2480 19 mW 15C — — CC
5955 – 6415 965 mW 15E — — CC EP MO
5955 – 7115 109 mW 15E — — CC EP MO
6535 – 6885 988 mW 15E — — CC EP MO
5180 – 5250 245 mW 15E — — CC MO
5250 – 5320 249 mW 15E — — CC MO ND
5500 – 5720 244 mW 15E — — CC MO ND
5745 – 5825 554 mW 15E — — CC MO
5815 475 mW 15E — — CC EP MO
5835 891 mW 15E — — CC EP MO
5845 458 mW 15E — — CC EP MO
5855 870 mW 15E — — CC EP MO
5865 – 5885 941 mW 15E — — CC EP MO
5955 – 7115 25 mW 15E — — CC EP MO

Frequency pairs from the FCC grant list; power, rule parts and notes from the grant of each application. Grant notes: CC = conducted, EP/ERP = radiated power, MO = mobile, ND = no duty-cycle averaging.

Grant conditions

Part 15 Spread Spectrum Transmitter. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (641 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antennas used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.14 W/kg and 1.59 W/kg, respectively.

Digital Transmission System. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (641 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antennas used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.55 W/kg and 1.59 W/kg, respectively.

15E 6 GHz Low Power Dual Client. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators.… (625 characters, open to read all)

This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antennas used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR and Power Density has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.77 W/kg and 1.59 W/kg, respectively.

15E 6 GHZ Very Low Power Device. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators.… (813 characters, open to read all)

This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Besides, the SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR value for body use conditions is 0.28 W/kg. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Unlicensed National Information Infrastructure TX. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be instal… (641 characters, open to read all)

Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antennas used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.80 W/kg and 1.59 W/kg, respectively.

History

Other devices by Acer Incorporated

All 35 FCC IDs of Acer Incorporated.

Recent 6VL devices

15E 6 GHZ Very Low Power Device devices granted closest in time to HLZMT7925B14L.

All 200 FCC IDs in class 15E 6 GHZ Very Low Power Device.

Recent 6CD devices

15E 6 GHz Low Power Dual Client devices granted closest in time to HLZMT7925B14L.

All 215 FCC IDs in class 15E 6 GHz Low Power Dual Client.

Recent DTS devices

Digital Transmission System devices granted closest in time to HLZMT7925B14L.

All 18017 FCC IDs in class Digital Transmission System.

Recent DSS devices

Part 15 Spread Spectrum Transmitter devices granted closest in time to HLZMT7925B14L.

All 10808 FCC IDs in class Part 15 Spread Spectrum Transmitter.

Recent NII devices

Unlicensed National Information Infrastructure TX devices granted closest in time to HLZMT7925B14L.

All 4768 FCC IDs in class Unlicensed National Information Infrastructure TX.